background image

Page 10 of 12

LAN port

The network connector integrates the system into a local area 

network. Please connect the EcHo Plus to your LAN if using any 

of the LAN features of the product.

Two LEDs on the connector indicate the following:

Color:

Off

On

Blink

Yellow

No Link

Link

Activity

Green

10Mbit

100Mbit

Factory default IP setting of the EcHo Plus is:

IP address:    

192.168.254.253

Subnet:   255.255.255.0

10/100Mbit:  

Auto

DHCP: 

  Disabled

Buttons

The eight front panel buttons are accessed by the end user to 

control the AV system in which EcHo Plus functions as the con-

troller. The buttons are numbered as shown to the right.

Each button has a tactile click feedback to ensure proper  

activation. Also, each button has an embedded red LED light to 

indicate current status of the AV system. 

Button function and LED indication are set up using the Neets 

Project Designer software.

USB port

The USB port is used exclusively for configuring the EcHo Plus 

from the Neets Project Designer software. It can’t be used to 

control any external devices.

The front panel USB port is located beneath the front glass 

and label.

The host USB port can power the control system while con-

figuring, so the included AC power adaptor is not needed when 

configuring the EcHo Plus. However, connecting the AC power 

adaptor and USB port at the same time is allowed, for example 

when changing configuration on an already installed unit.

The USB connector for connecting to the EcHo Plus is type 

“mini USB B 5P”. (It is available on the web as a USB A to Mini 

USB B 5P).

A/V MUTE

OFF

DVD

PC 1

BLUERAY

PC 2

SCREEN

1

5

2

6

3

7

4

8

Neets Control

EcHo Plus, DK

P/N: 310-0252

LAN

GND

GND

I/O 1

I/O 2

I/O 3

PWR

NDA

NCL

GND

GND

TX-1

TX-2

RX-1

GND

12V

A/V MUTE

OFF

DVD

PC 1

BLUERAY

PC 2

SCREEN

Summary of Contents for echo plus

Page 1: ...Neets Control EcHo Plus EcHo Plus EU P N 310 0152 EcHo Plus DK P N 310 0252 User Manual...

Page 2: ...ge the specification and functions of this product without any notice Check www neets dk for the latest updated version ogf this manual Questions AFTER reading this manual can be addressed to your loc...

Page 3: ...components inside These openings must never be blocked by other objects Do not use this equipment near water To reduce the risk of fire or electric shock do not expose this apparatus to rain or moistu...

Page 4: ...t 3 Contents 4 Description 5 Specifications 6 Quick guide to the EcHo Plus 7 Connections and Controls 8 Power input port 8 I O ports 8 RS 232 port 8 RS 232 IR port 9 NEB port 9 LAN port 10 Buttons 10...

Page 5: ...you are ready to begin EcHo Plus is a perfect choice for the classroom meeting or conference room and is easy to install EcHo Plus can control devices through IR RS232 or even LAN EcHo Plus is availa...

Page 6: ...z to 150 KHz Product number 310 0152 EcHo Plus EU 310 0252 EcHo Plus DK Approvals IEC EN 61000 6 1 IEC EN 61000 6 2 Input Output Ports 3 x I O Input trigger low 1VDC Input trigger high 4VDC Output typ...

Page 7: ...el glass with label for button description 4 Mini USB for programming behind front glass Rear Number Description 1 RS 232 port Bi directional 2 RS 232 or IR port Uni directional 3 NEB bus port 4 Input...

Page 8: ...through a FET transistor also called open drain collector function Each I O can draw up to 24VDC 500mA When used as inputs the applied voltage must be below 1 VDC to be accepted as LOW and above 4 VDC...

Page 9: ...ol EcHo Plus DK P N 310 0252 LAN GND GND I O 1 I O 2 I O 3 PWR NDA NCL GND GND TX 1 TX 2 RX 1 GND 12V Neets Control EcHo Plus DK P N 310 0252 LAN GND GND I O 1 I O 2 I O 3 PWR NDA NCL GND GND TX 1 TX...

Page 10: ...V system Button function and LED indication are set up using the Neets Project Designer software USB port The USB port is used exclusively for configuring the EcHo Plus from the Neets Project Designer...

Page 11: ...ject are connected o Check that the NEB units used in the project are configured correctly o After doing one of the above remove the power to the control system for 20 sec before recon necting the pow...

Page 12: ...or more of the Neets network units used in the current project needs a firmware upgrade before it will work with this project 1 Off 2 Off 3 Flashing 4 Off Error in serial number o You need to return...