Control board indications

The control board indications

A.

When the mains plug is connected the light

emission diodes indicate fixed light and an alarm

signal sounds a short time.

B.

The light emission diode indicates blinking

green light: The FilterCart has been connected to

the mains (stand by).

C.

As the FilterCart has been started the light

emission diode indicates fixed green light. The fan

is in operation.

D.

The FilterCart is ready for use and after a while

the light emission diode indicates fixed green light.

After use for a certain time, the airflow will be reduced

through the extraction arm and the pressure drop

will increase, which will result in having to change

the filter cartridge.

E.

The light emission diodes indicate fixed light: The

pressure drop has increased. Pre-warning for

changing the filter cartridge.

F.

The light emission diodes indicate fixed light and

after about 30 s an intermittent alarm signal starts.

Change the filter cartridge.

If you want to finish the work in progress before the

filter cartridge is changed, the alarm signal can be

stopped by pushing 

once

 on the start button. The

alarm signal activates after about 10 minutes.

Pushing

 twice 

on the start button makes a fan stop.

As an alternative the fan can be stopped with the

switch on the fume extractor hood.

G.

The light emission diode indicates blinking red

light = alarm memory. The FilterCart has been

stopped after the alarm start (according to above),

for example at work shifts. The filter cartridge has

to be changed.

H.

The light emission diode indicates fixed red light

and an intermittent alarm signal starts. The overload

protector has been released. 

Examine the reason

and reset the overload protector by pushing the
"Motor Protector Reset"- button.

Summary of Contents for W 3 200 V 3~

Page 1: ...FilterCart FilterCart No 144029 03 2019 04 16 S M E T S Y S R E T L I F N O I T C A R T X E INSTRUCTION MANUAL W 3 200 V 3 ...

Page 2: ...ISO 15012 1 non alloy steel to high alloy steel with nickel and chromium 30 also pay attention to local regulations horizontally swiveling arm 240 Dimensions Foreword To guarantee a correct function and a minimal service it is important to read and understand the information in this instruction manual The manual contains important work safety regulations and warning directions which have to be rea...

Page 3: ...Start the FilterCart with the switch A or as an alternative with the switch on the hood of the extractor arm The light emission at C indicates fixed green light The fan operates Overload protector The FilterCart is equipped with an overload protector which means that the power will disconnect auto matically if the fan motor should be overloaded C Red light emission light indicates disconnected pow...

Page 4: ...Cart must not be used for extracting toxic substances except welding fumes The FilterCart must not be used without filter cartridge and casing The FilterCart must not be used in closed rooms without general ventilation 4 The extraction arm should be positioned with the wheels locked The Filtercart should be moved from behind and with wheels unlocked The hood is provided with an efficient spotlight...

Page 5: ...crease which will result in having to change the filter cartridge E The light emission diodes indicate fixed light The pressure drop has increased Pre warning for changing the filter cartridge F The light emission diodes indicate fixed light and after about 30 s an intermittent alarm signal starts Change the filter cartridge If you want to finish the work in progress before the filter cartridge is...

Page 6: ...ccentric locks and remove the filter casing 3 Use the plastic bag which comes with the new filter cartridge and pull it over the used cartridge Fold the plastic bag under the cartridge 4 Use a duster to wipe off the filter cartridge contact surfaces in the FilterCart Put the duster in the plastic bag with the filter cartridge and close the bag with the band supplied 5 Handle the used filter cartri...

Page 7: ...nd that the seal is downwards Check that the seal not is damaged Note the UP arrows 6 Refit the top cover Fasten it securaly Maintenance Is recommended at least once a year WARNING Risk for personal injuries Disconnect the mains connection cable before starting any maintenance work Use necessary personal safety equipment Change the filter cartridge and optional HEPA filter if necessary Check the a...

Page 8: ...onformity We AB Ph Nederman Co declare under our sole responsibility that the Nederman product FilterBox Kit W3 with accessories to which this declaration relates are in conformity with the following Directives 2006 42 EC 2014 30 EU 2011 65 EU Standards EN 60204 1 EN ISO 12100 2010 EN ISO 15012 2013 EN 61000 3 3 EN 61000 6 2 EN 61000 6 4 For W3 products The products are approved by BGIA Institut f...

Reviews: