FilterCart
3
Mounting instruction, hood
1
3
4
2
N.B.
cable
with loop
The hood must be fitted according to these
pictures. Adjust the links so that the hood
could be easily positioned.
A
B
C
Initial operation
1.
Ensure the FilterCart has not been
damaged during transport.
2.
Check that the mains voltage is the same
as on the sign plate of the FilterCart.
3.
Fit a suitable plug to the connection cable.
Connect the connection cable with plug to the
mains. The light emission diodes at
B
indicate
fixed lights and an alarm signal sounds for a
short time. The light diode at
C
indicates blinking
green light (stand by).
4.
Start the FilterCart with the switch
A
or as an
alternative with the switch on the hood of the
extractor arm. The light emission at
C
indicates
fixed green light: The fan operates.
Overload protector
The FilterCart is equipped with an overload protector
which means that the power will disconnect auto-
matically if the fan motor should be overloaded.
C.
Red light emission light indicates: disconnected
power and released overload protector.
The overload protector will re-set automatically.
Important!
If the fan does not start, the phase-sequence
relay has released. The light emission diode at
C
indicates red light and an alarm signal starts.
Alternate 2 phases in the connection cable plug.
Spare parts
See www.nederman.com / spare parts.
When ordering always state part no. and control no.
(see type label of the product).