background image

FilterCart

3

Mounting instruction, hood

1

3

4

2

N.B.

 cable

with loop

The hood must be fitted according to these

pictures. Adjust the links so that the hood

could be easily positioned.

A

B

C

Initial operation

1.

Ensure the FilterCart has not been

damaged during transport.

2.

Check that the mains voltage is the same

as on the sign plate of the FilterCart.

3.

Fit a suitable plug to the connection cable.

Connect the connection cable with plug to the

mains. The light emission diodes at 

B

 indicate

fixed lights and an alarm signal sounds for a

short time. The light diode at 

C

 indicates blinking

green light (stand by).

4.

Start the FilterCart with the switch 

A

 or as an

alternative with the switch on the hood of the

extractor arm. The light emission at 

C

 indicates

fixed green light: The fan operates.

Overload protector

The FilterCart is equipped with an overload protector

which means that the power will disconnect auto-

matically if the fan motor should be overloaded.

C.

Red light emission light indicates: disconnected

power and released overload protector.

The overload protector will re-set automatically.

Important!

If the fan does not start, the phase-sequence

relay has released. The light emission diode at 

C

indicates red light and an alarm signal starts.

Alternate 2 phases in the connection cable plug.

Spare parts

See www.nederman.com / spare parts.

When ordering always state part no. and control no.

(see type label of the product).

Summary of Contents for W 3 200 V 3~

Page 1: ...FilterCart FilterCart No 144029 03 2019 04 16 S M E T S Y S R E T L I F N O I T C A R T X E INSTRUCTION MANUAL W 3 200 V 3 ...

Page 2: ...ISO 15012 1 non alloy steel to high alloy steel with nickel and chromium 30 also pay attention to local regulations horizontally swiveling arm 240 Dimensions Foreword To guarantee a correct function and a minimal service it is important to read and understand the information in this instruction manual The manual contains important work safety regulations and warning directions which have to be rea...

Page 3: ...Start the FilterCart with the switch A or as an alternative with the switch on the hood of the extractor arm The light emission at C indicates fixed green light The fan operates Overload protector The FilterCart is equipped with an overload protector which means that the power will disconnect auto matically if the fan motor should be overloaded C Red light emission light indicates disconnected pow...

Page 4: ...Cart must not be used for extracting toxic substances except welding fumes The FilterCart must not be used without filter cartridge and casing The FilterCart must not be used in closed rooms without general ventilation 4 The extraction arm should be positioned with the wheels locked The Filtercart should be moved from behind and with wheels unlocked The hood is provided with an efficient spotlight...

Page 5: ...crease which will result in having to change the filter cartridge E The light emission diodes indicate fixed light The pressure drop has increased Pre warning for changing the filter cartridge F The light emission diodes indicate fixed light and after about 30 s an intermittent alarm signal starts Change the filter cartridge If you want to finish the work in progress before the filter cartridge is...

Page 6: ...ccentric locks and remove the filter casing 3 Use the plastic bag which comes with the new filter cartridge and pull it over the used cartridge Fold the plastic bag under the cartridge 4 Use a duster to wipe off the filter cartridge contact surfaces in the FilterCart Put the duster in the plastic bag with the filter cartridge and close the bag with the band supplied 5 Handle the used filter cartri...

Page 7: ...nd that the seal is downwards Check that the seal not is damaged Note the UP arrows 6 Refit the top cover Fasten it securaly Maintenance Is recommended at least once a year WARNING Risk for personal injuries Disconnect the mains connection cable before starting any maintenance work Use necessary personal safety equipment Change the filter cartridge and optional HEPA filter if necessary Check the a...

Page 8: ...onformity We AB Ph Nederman Co declare under our sole responsibility that the Nederman product FilterBox Kit W3 with accessories to which this declaration relates are in conformity with the following Directives 2006 42 EC 2014 30 EU 2011 65 EU Standards EN 60204 1 EN ISO 12100 2010 EN ISO 15012 2013 EN 61000 3 3 EN 61000 6 2 EN 61000 6 4 For W3 products The products are approved by BGIA Institut f...