Appendix B: Maintenance checklist
Copy the maintenance checklist, fill it in and save it as a service record.
For values, note the value in the result column, otherwise a tick will suffice if
the item has been performed or considered.
WARNING!
Risk of personal injury.
No zone present during installation, service and cleaning.
NOTE!
If an inspection result (for example, a measured value) differs
significantly from a previous result, find the cause for the difference.
Unit No.
Date:
Operating hours:
Performed by:
Control items
Reference
Result
Notes
INTERNAL CLEANING OF HOOD AND HOSE
Wet or dry cleaned.
Components dryed and refitted.
NEX S housing is properly grounded.
Earth continuity < 100 ohm
REGULAR MAINTENANCE, ONCE A YEAR
NEX S housing is properly grounded.
Earth continuity < 100 ohm
Hose intact.
If necessary, change the hose.
Mounting of the arm on wall or ceiling
checked
.
Links adjusted.
Spring and spring holders functional
Suction capacity in the hood
is sufficient.
Links adjusted.
External cleaning hood and hose.