NEX D/DX
EN
3.2 Technical data
Table 3.1 Technical data
NEX D/DX
Noise level
*
:
54–81 dB(A)
Weight:
• NEX D/DX 2m
17 kg
• NEX D/DX 3m
21 kg
• NEX D/DX 4m
28 kg
• NEX D/DX 5m
32 kg
Hose diameter
Ø 160 mm
Recommended airflow
**
Maximum 1700 m
3
/h
Recommended temperature use
Maximum 70 °C
Zone, dust
***
:
• NEX DX
21, 22 ***
• NEX D
22 ***
*
Measured according to ISO 11201.
**
Also, apply to local directions.
*** For use in respective zones according to ATEX-work directive 1999/92/EEC.
4 Installation
4.1 90°-bend in hanging or standing po-
sition
The NEX D/DX arm is recommended to be mounted
according to
item A, with the 90°-bend in
hanging position.
The NEX D/DX arm can also be mounted according to
item B, with the 90°-bend in standing position. How-
ever, the arm holder must then be revolved 180°. Re-
volve the arm holder in the following way:
1
Loosen the four screws fitting the arm holder to
the 90°-bend.
2
Move the arm holder approximately 17 mm away
from the 90°-bend.
3
Revolve the arm holder 180°.
4
Move the arm holder back towards the 90°-bend.
5
Fasten the four screws.
4.2 Mounting NEX D/DX
See,
. The extraction arm can be
mounted on wall or ceiling together with a wall brack-
et. Ensure that the surface, on which to mount the
arm, is level and use the wall bracket to mark the
holes.
Use locking fixing bolts and nuts suitable for the wall
material. The bolts much each stand a torque force
of minimum 1200 N (2m), 1900 N (3m), 3200 N (4m),
4500 N (5m). Use a spirit level and make sure that the
extraction arm is fitted in a horizontal position.
Check that proper measures have been taken to avoid
all types of electrical stray currents to and/or from the
piping system and electrical wiring.
NOTE!
Make sure the NEX D/DX housing is properly
grounded. See
and
.
NOTE!
Fill out the installation protocol when finished
installing the NEX D/DX.
4.2.1 Rotary stop
Should only be fitted when the arm is mounted in a
360° rotating position, see
.
18
Summary of Contents for NEX 2 m
Page 10: ...NEX D DX 2300 mm 1900 mm A B 2b 2a 6 4 NEX 2 m NEX 3 m 3 NEX 5 m 5 7 10 ...
Page 12: ...NEX D DX NEX D 1 ground cable NEX DX 2 ground cables 14 12 13 10 15 16 17A 17B 10 ohm Ω 11 12 ...
Page 13: ...NEX D DX 360 A 12 A B 5 5 or oder ou o of tai eller 13 13 ...
Page 14: ...NEX D DX or oder ou o of tai eller 14 A 13 mm B 1 3 m m C1 C2 C3 15 14 ...
Page 15: ...NEX D DX C5 C4 C7 C6 C8 16 15 ...
Page 67: ...NEX D DX Voci di controllo Riferimento Risultato Note Collegamenti regolati IT 67 ...
Page 75: ...NEX D DX Controlepunten Referentie Resultaat Opmerkingen Verbindingen afgesteld NL 75 ...
Page 98: ...www nederman com ...