TRANSIT Ultimate | installation guide
14/40
3.2
RS485-OSDP wiring
The RS485-OSDP wiring should be connected to the RS485 connections on the OSDP Installation Board (OSDP-IB) or
directly to the PCC485. See wiring picture below.
For point-to-point communication enable the termination resistor. PCC485 switch 1 to ON position. See picture below.
Figure 8: RS485-OSDP point-to-point wiring
For multi-drop communication disable the termination resistor on the PCC485 on all devices except the last device. The
termination resistor should be enabled on the last device in a multi-drop communication system. See picture below.
Figure 9: RS485-OSDP multi-drop wiring
For more details refer to the separate PCC485 installation guide.