36
NED
XCM4085DLMT4
UME-0058-03
4.2.14 Setting Exposure Time - Readout Time
Prolongs the line period without changing the exposure time.
Format 2 CMD
□
VAL1 CR
CMD pad
VAL 0 to 1048575 (XCM4085DLMT4 : 0 to 12336.176µs)
<Example>
pad
□
10 CR
>OK
>pad 10
4.2.15 Returning the Camera Settings status
Returns the current camera settings.
Format 1 CMD CR
CMD sta
<Example>
sta CR
>OK
>Type=XCM4085DLMT4
>Ver. =1.12_0x0217
>Serial=209
>gax 0
>gdx 0
>odx 0
>inm 0
>int 0, 10000
>pad 0
>shc 1,200
>tpn 0
>rev 0
>voa 0,0
>vod 0
>d 0
>gamma 0, 1000
>sta