35
NED
XCM4085DLMT4
UME-0058-03
4.2.12 Initializing Pixel Correction Data
Deletes user arbitrary pixel correction data and resets to factory settings.
All of data of analog gain reset to factory settings except for the gain setting and
offset setting of the camera setting.
When the camera is shipped out, the data of factory black pixel correction and
factory white pixel correction is stored.
It takes about 2 minutes to complete this command task since the command is sent.
Note
:
While the command task is executed, the camera does not respond for about
1 minute. After that, OK comes back from the camera.
Do not turn off the power supply of the camera during this execution or
the camera may be damaged.
Format 1 CMD CR
CMD calibde
<Example>
calibdef CR
>OK
>calibdef
4.2.13 Setting Pixel Correction
Sets pixel correction.
Format 3 CMD
□
VAL1
□
VAL2 CR
CMD
shc
VAL1
0,1,2,3,4,5
(0:Correction OFF
1:Factory black corfactory white correction
2:Factory black coruser arbitrary white correction
3:Not used
4:User arbitrary black corfactory white correction
5:User arbitrary black coruser arbitrary white correction)
VAL2 0 to 255 (Setting correction level:8bit)
<Example>
shc
□
1
□
200CR (for Factory white correction, Correction level 200)
>OK
>shc 1,200