6
OPERATING INSTRUCTIONS - Customer
Please refer to the “Nectre Wonderfire” Operating, Installation and Servicing Instructions.
INSTALLATION INSTRUCTIONS
Preliminary
• This appliance must be installed in accordance with the AGA Gas Installation Code AS5601 /
AG601 Clauses 5.12.13.2 to 5.12.13.5 and appropriate Australian Standards to meet the zero
clearance rating.
• The Nectre Wonderfire Gas Fire is only to be used with the gas type specified for the unit.
• It is recommended that a secondary guard complying with AS 2286 be installed.
• As always, ensure that loose fabrics such as curtains and furniture cannot touch the appliance.
It is recommended that a fire guard be used with the appliance.
• The spacers on the sides and back of the box are to provide clearance to combustible
materials.
• Do not allow combustible materials to touch the box.
• There must be a minimum of 50mm gap between the gather and any combustible materials.
• The front opening of the box is 500mm wide and 570mm high.
• The overall dimensions of the box is 650mm wide, 300mm deep and 805mm high. (Dimensions
include zero clearance spacers and the gather but not the facia or guardette if fitted).
• Packaging and transit protection must be removed from the appliance prior to installation. This
includes pallet, plastic wrap, temporary labels and foam protection.
Fitting the unit
•
If fitting to an existing fireplace,
it must be at least 505mm wide, 275mm deep and 575mm
high to suit the Nectre fan forced convector box (with the zero clearance spacers removed).
• The chimney should also be swept and inspected to see if it is in sound condition.
• The chimney must be a minimum area of 22 000mm2 (e.g. 150x150mm if masonry or 150mm
diameter if round metal flue).
• A 150mm AGA approved Gas Cowl must be fitted.
TO THE INSTALLER
This appliance must only be installed by an authorized person in accordance with these
instructions and with the AGA gas installation code. Please ensure that your workmanship, like
ours, is of the highest quality so that our customer is fully satisfied with the installation and
operation of this Gas Fire. If you have any questions please call us: 1300 554 155.