Please refer to the “Nectre Wonderfire” Operating, Installation and Servicing Instructions.

INSTALLATION INSTRUCTIONS

Preliminary

• This appliance must be installed in accordance with the AGA Gas Installation Code AS5601 /

AG601 Clauses 5.12.13.2 to 5.12.13.5 and appropriate Australian Standards to meet the zero

clearance rating.

• The Nectre Wonderfire Gas Fire is only to be used with the gas type specified for the unit.
• It is recommended that a secondary guard complying with AS 2286 be installed.
• As always, ensure that loose fabrics such as curtains and furniture cannot touch the appliance.

It is recommended that a fire guard be used with the appliance.

• The spacers on the sides and back of the box are to provide clearance to combustible

materials.

• Do not allow combustible materials to touch the box.
• There must be a minimum of 50mm gap between the gather and any combustible materials.
• The front opening of the box is 500mm wide and 570mm high.
• The overall dimensions of the box is 650mm wide, 300mm deep and 805mm high. (Dimensions

include zero clearance spacers and the gather but not the facia or guardette if fitted).

• Packaging and transit protection must be removed from the appliance prior to installation.  This

includes pallet, plastic wrap, temporary labels and foam protection.

Fitting the unit

If fitting to an existing fireplace,

it must be at least 505mm wide, 275mm deep and 575mm

high to suit the Nectre fan forced convector box (with the zero clearance spacers removed).

• The chimney should also be swept and inspected to see if it is in sound condition.
• The chimney must be a minimum area of 22 000mm2 (e.g. 150x150mm if masonry or 150mm

diameter if round metal flue).

• A 150mm AGA approved Gas Cowl must be fitted.

TO THE INSTALLER

This appliance must only be installed by an authorized person in accordance with these

instructions and with the AGA gas installation code. Please ensure that your workmanship, like

ours, is of the highest quality so that our customer is fully satisfied with the installation and

operation of this Gas Fire. If you have any questions please call us: 1300 554 155.

Summary of Contents for WONDERFIRE FFB

Page 1: ...ertified as a Space Heater WONDERFIRE FFB Fire Fan Box INSTALLATION OPERATING MANUAL Nectre Wonderfire fire boxes are approved to be installed as a zero clearance firebox and are designed to operate o...

Page 2: ...tructions or b it has been installed in an outdoor setting 4 Limit of Liability The warranty provided under this warranty is limited to replacement or repair of the Gas Burner only at our option To th...

Page 3: ...THE APPLIANCE OR DRAUGHT OF CHIMNEY OR FLUE DO NOT MODIFY THIS APPLIANCE THIS APPLIANCE IS DESIGNED TO OPERATE WITH LUMINOUS FLAMES THIS MAY EXHIBIT SLIGHT CARBON DEPOSITS Permanent ventilation of th...

Page 4: ...4 CONTENTS Contents 4 User Instructions 5 Installation Instructions 6 Servicing Details 8 Glen Dimplex contact information 12...

Page 5: ...etal surfaces simply wipe over with a damp cloth Do not use harsh cleaning agents or solvents Ceramic coals Lightly vacuum with a soft brush attachment Pilot Light check for lint and dust vacuum as ne...

Page 6: ...and 570mm high The overall dimensions of the box is 650mm wide 300mm deep and 805mm high Dimensions include zero clearance spacers and the gather but not the facia or guardette if fitted Packaging an...

Page 7: ...al to the chimney flue area The gather should be sealed to the fan box using a high temp silicon or a high temp fire flue sealant Gas and electrical Gas connection is to a BSP fitting connected to the...

Page 8: ...8 SERVICING MAINTENANCE FAULT FINDING DETAILS Please refer to the Nectre Wonderfire Operating Installation and Servicing Instructions WIRING DIAGRAM...