Nectre Bakers Oven model have been tested & complies to New Zealand National 
Environmental Safety Test Standard 

- AS/NZS 2918:2001     

 

Overall Dimensions 

550mm Wide x 572 mm Deep x 825mm High 

Weight 

170 kg 

 

Bakers Oven is a cooking appliance.  Consult your local council for clarification on rules 
appertaining to the installation of wood-fired cooking appliances/  

 

Approx. Heating Capacity 

Small to Medium Homes (2-3 bedrooms) 

 

 

Flue Shield 

900mm Long 180

0

 circumference or 900mm long Masport 

Stainless Steel Double Flue Shield 

Flue System 

Standard 4.2M Long,150mm Masport Flue System with a 
dropbox or flue system with dropbox that has been tested 
and comply with ASNZS 2918:2001 Appendix F. 

Floor Protector Requirement 

Minimum 12mm thick Floor Protector made of   

-  12mm non-combustible fiber cement board or  
-  Combination of 6mm tile underlay & 8mm tiles  

 

Clearances to Combustibles

 

Parallel Installation 

Corner Installation 

 

 

A- Rear Panel to Rear Wall 

125 mm 

C- Glass to Floor Protector Front  

300 mm 

B-Cooktop Edge to Side Wall 

350 mm 

E- Cooktop Corner to Wall  

350 mm 

C- Glass to Floor Protector Front  

300 mm 

H- Flue Centre to Wall 

640 mm 

D- Floor Protector Side  

100 mm 

L- Floor Protector Diagonal  

1618 mm 

F- Flue Centre to Rear Wall 

260 mm 

M- Floor Protector Side 

1303 mm 

G- Flue Centre to Side Wall 

625 mm 

N- Flue Centre to Floor 
     Protector Front 

713 mm 

I- Floor Protector Front Edge 

450 mm 

R- Flue Centre to Wall Corner 

905 mm 

J- Floor Protector Width 

750 mm 

WW- Overall Width of Fire 

550 mm 

K- Floor Protector Depth  

973 mm 

DD- Overall Depth of Fire 

572 mm 

 

 

HH- Overall Height of Fire  

825 mm 

Seismic Restraint

 - In New Zealand, it is required that the wood burner and floor protector are 

secured to prevent shifting in the event of an earthquake.  This is best done by fastening the wood 
burner right through the protector to the floor, using 8mm DynaBolts or 8mm coach screws or 
equivalent toggle fasteners for wooden floors of appropriate lengths.  Seismic holes are at the rear 
of the burner. 

Summary of Contents for Baker's Oven

Page 1: ...USE THIS MANUAL FOR INSTALLATION OF BAKERS OVEN IN NEW ZEALAND AND AUSTRALIA Date 30th Aug 2020 PART ID 570115 NZ V2 0...

Page 2: ......

Page 3: ...Keep instructions in a safe place for future reference Glen Dimplex New Zealand Ltd reserves the right to change specifications the content of this manual or the design of its product without prior n...

Page 4: ...aland have varying regulations about the installation and operation of wood fired cooking appliances and you and your installer should be aware of these POSITIONING THE NECTRE The clearances from the...

Page 5: ...ipe must be a minimum of 600mm above the ridge of the roof if the flue penetrates the roof within 3m of the ridge Or to be of sufficient height to be 3m from the roofline horizontally but a minimum he...

Page 6: ...al moisture content FLUE FIRE In the event of a chimney fire close the primary air spindle control to suffocate the fire WHERE A WATER JACKET IS FITTED Wetbacks for baker s oven are made of boiler gra...

Page 7: ...Guidelines for low pressure hot water systems header tank open vented Guidelines for low pressure hot water systems low level open vented...

Page 8: ...ncinerator only burn appropriately seasonedwood Do not overload the appliance with wood Do not operate the stove with the firebox door open Do not operate the appliance with a cracked glass This appli...

Page 9: ...the damper This directs the flames and flue gases down the sides and around the oven Keep the fire burning briskly until the oven is up to temperature NOTE the temperature gauge on the oven door is o...

Page 10: ...e strip should be set leaving a gap of 1mm between the edge of the strip and the front of the Baker s Oven This gap provides secondary air supply 4 Door Seal The door seal is a 13mm round fiberglass b...

Page 11: ...bles Parallel Installation Corner Installation A Rear Panel to Rear Wall 125 mm C Glass to Floor Protector Front 300 mm B Cooktop Edge to Side Wall 350 mm E Cooktop Corner to Wall 350 mm C Glass to Fl...

Page 12: ......

Page 13: ...nnaire Question Please tick appropriate remark 1 General presentation of Product Excellent Good Ok Needs to Improve 2 Styling and Looks Excellent Good Ok Needs to Improve 3 Packaging Excellent Good Ok...

Page 14: ......

Page 15: ...or travel costs Consumers may have additional rights under the Consumer Guarantees Act 1993 New Zealand or the Australian Trade Practices Act 1974 including the Australian Consumer Law Conditions This...

Page 16: ...left the control of Glen Dimplex Direct indirect or consequential losses or special damages of any kind including costs of collection and delivery other than repair or replacement of products or compo...

Reviews: