14
© by NECTA VENDING SOLUTIONS SpA
0401 171 - 02
TECHNICIAN MENU
Using the programming procedures described in this sec-
tion, it is possible to set all variables regarding machine
configuration.
The machine is preset to “technician menu” mode when
connected to the power supply with the payment system
door open and the programming button is pressed twice.
N.B. When pressing the button again while in the
programming menu, the machine will return to “load-
ing” mode.
The keys “ ” and “ ” scroll through the technician menu
items, which include:
Failures
Reading present failures
Reading drum/slider failures
Delete
Lighting
Lamps On/Off
with out of service
Prog. parameters Cash
Prices
Coin mech.
Decimal point
Bonus
Drums/sliders
Drum
parameters
Slider
parameters
Cold parameters
Temperature
Defrosting
Air adjustment
Cooling unit
Display
Language
User messages
Promotional
message
Personal. strings
Euro
Display
counters
Miscellaneous
Password
Energy saving
Progr. level
Statistics
Partial
Total
Print relative
Partial
Total
Display
Selections
Time bands
Failures
Coin mech.
Display relative
Selections
Time bands
Failures
Coin mech.
Delete
Partial
Total
Cancel relative
Partial
Total
Test
Drum
Slider
Complete selection
Miscellaneous
Machine info
Installation date
Machine code
Operator code
Initialising
GSM
Pin code
Pre-alarms
EVADTS
Pass code
Security code
Connection
PRESENT FAILURES
READING
When the “Failure” function is displayed, press the confirm
button “ ” to display the present failures.
If no failures are currently present, after pressing the
confirm button “ ” the message “End failures” will be
displayed.
The monitored failures are:
Compressor
The machine is locked if the compressor runs nonstop for
more than 24 hours.
Coin mechanism
The machine is locked if it receives a pulse longer than 2
seconds on a validator line or the communication with the
serial coin mechanism does not take place for more than
30 seconds (Executive protocol) or 75 seconds (BDV
protocol).
RAM Data
One or more areas of the RAM contain wrong data which
was corrected with the default values.
The machine will continue to function, but it would be
advisable to initialise as soon as possible.
Probe
The machine is locked after 5 minutes if the internal
temperature sensor is disconnected; the display will indi-
cate a temperature of -11° C.
The machine is locked after one hour if a sensor short
circuit is detected; in this case the display will indicate a
temperature of +41° C.
Machine control board
Failed dialogue between C.P.U. board and machine con-
trol board.
Gas temperature sensor
The display will indicate the message if a short-circuit is
detected on the temperature control sensor of the hot-gas
evaporator.
Summary of Contents for StarFood
Page 1: ...INSTALLATION USE AND MAINTENANCE MANUAL UK English StarFood DOC NO H 171U 02 EDITION 3 2004 01...
Page 2: ......
Page 4: ......
Page 59: ...by NECTA VENDING SOLUTIONS SpA NOTE...
Page 60: ...Sx35703...
Page 61: ...StarFood...
Page 62: ...Sx35803...
Page 63: ...StarFood...
Page 64: ...by NECTA VENDING SOLUTIONS SpA NOTE...
Page 65: ...by NECTA VENDING SOLUTIONS SpA NOTE...
Page 66: ...by NECTA VENDING SOLUTIONS SpA NOTE...
Page 68: ......