Features
Features Manual
177
SMDR Report Format
Character
Position Field
Definition
Header
Line
1-60 Spaces
61-70 MM/DD/YYYY
71 Space
72-75 PAGE
76 Space
77-79
Report page number (e.g., 001)
CR & LF
Header Line 2
1-3 Spaces
4-8 CLASS
9-10 Spaces
11-14 TIME
15-18 Spaces
19-22 LINE
23-26 Spaces
27-34 DURATION
35-36 Spaces
37-43 STATION
44-46 Spaces
47-53 DIALLED
54 Space
55-61 No./CLI
62-63 Spaces
64-70 RD/COST
71 Space
72-78 ACCOUNT
CR & LF
Carriage return and line feed
SMDR Record
1-2
Call record number 01-55
3 Space
4-8
Call type (e.g., POT for outgoing)
9 Space
10-14
Time in 24 hour clock (HH:MM)
15 Space
16-25
Line number (e.g., 001)
26 Space
27-34
Call Duration (HH:MM:SS)
35 Space
36-45
Station number (STA, space, nnnn) or name
46 Space
47-61
Number dialled (15 digits maximum)
62-63 Spaces
64-70
Ring duration for incoming. Cost for outgoing
71 Space
72-80
Account number or NO ANSWER