![background image](http://html1.mh-extra.com/html/nec/xen-master/xen-master_system-hardware-manual_4082722136.webp)
NEC Australia Pty Ltd
Xen Master & Xen Axis
5 - 118
Installing Electronic Telephone Units
A6-3
240
00-6
42-
01 –
R
e
leas
e 4
.0
M
a
y
20
01
In the Xen Master, the MIFM-U13 can be installed in the
ISA slot or the first or second Interface Slot (S1, S2) in the
basic KSU. Note however that if the MIF-Modem is
required, the MIFM-U13 ETU must be installed in slot S1
or S2, NOT the ISA slot. The MIFM-U13 ETU cannot be
installed in an expansion KSU.
In the Xen Axis, the MIFM-U13 ETU must be installed in
the ISA Slot S2.
3.5.3
Switch Settings
Refer to Table 5-2 MIFM-U13 Switch Settings for
MIFM-U13 ETU default switch settings.
3.5.4
LED Indications
LIVE LED indications are listed below.
✆
Blinking Red
Normal Operation
✆
Steady Red
Operation Stopped (power still on)
✆
Off No
power
LED1 indications are listed below.
✆
Steady
Red
Problem while loading FROM
EEPROM (when using this mode)
✆
Steady
Red
PC Programming or LCR
Programming is connected
✆
Flashing Red
Loading FROM from EEPROM
Table 5-2 MIFM-U13 Switch Settings
SW2-1
SW2-2
Description
Off
Off
Normal Operation
On
Off
Factory Test
Off
On
Not Used
On
On
Flash ROM load from
EPROM
SW1
Description
On
System boot by Flash ROM
Off
System boot by EPROM