4 of 12
ISSUED: 02-21-13 SHEET #: 145-9017-1
If CK02## Wall Plate Connector Kit is not available use diagram below to determine vertical spacing.
If CK02## Wall Plate Connector Kit is not available use diagram below to determine horizontal spacing.
To determine edge of second mount, add (
Z
) to edge or fi rst mount.
Vertical Spacing Location
Horizontal Spacing Location
Vertical Location
X - 10.00 + (.750 OR 1.580) = (Y1 OR Y2)
DISPLAY WIDTH - (35) = Z (SPACING BETWEEN MOUNTS)
Horizontal Location
DISPLAY WIDTH
DISPLAY
HEIGHT
X
Y2
Y1
.750
1.580
10.00
16.00"
20.00"
24.00"
17.50"
Z
To determine lower mounting slot position of second mount, add display height to (
Y1
) or (
Y2
)