Issue 1.0
UNIVERGE SV8100
3 - 12
Real unit ID : 12H
Version : 1.8
Firmware loaded onto the Blade
Lines / unit : 8
Number of ports on the card (8ESIU)
Block switch : RUN
Block switch set to RUN
Timeslot : 000H-00FH (16)
slot info 03
Slot information)
Slot ID : 3
Status : RUNNING
Logical unit ID : BRIU
Dump down message : Disable
Number of Tx errors : 0
Slot started delay : 468.99sec.
Common unit driver information)
Slot ID : 3
Real unit ID : 60H
Version : 3.3
Firmware loaded onto the blade
Lines / unit : 2
Number of ports on the card (2BRIU)
Block switch : BLOCK
Block switch set to BLOCK
Timeslot : 040H-043H (4)
BRIU driver information)
P
To reset the Blade installed in a slot:
slot reset nn
Where nn is the slot number 01 to 10 in hexadecimal.
The Blade is reset, any calls in progress at the Blade are disconnected.
The Blade operates normally after the reset.
The reset has the same operation as removing and re-installing the Blade.
(example – to reset the Blade in slot 3 =
slot reset 03
)
R
Detector
Enter
Function
DIM Output
Detector
List the status of the
DTMF/Tone detectors on
the CD-CP00-US (and
DSPDB if installed).
Number of Channels = 64
CPRU = 32 , DSPDBU = 32
No Type Status Target
01(1401) DTMF ACTIVE 000d
02(0000) NOT USED READY 0000
03(0000) NOT USED READY 0000
04(0000) NOT USED READY 0000
05(0000) NOT USED READY 0000
: : : :
64(0000) NOT USED READY 0000
Summary of Contents for Univerge SV8100
Page 2: ......
Page 3: ...System Maintenance Manual INT 2057 UNIV ISSUE 1 0...
Page 4: ......
Page 6: ......
Page 8: ...THIS PAGE INTENTIONALLY LEFT BLANK...
Page 40: ...Issue 1 0 UNIVERGE SV8100 2 22 System Maintenance NOTES...
Page 76: ...Issue 1 0 UNIVERGE SV8100 3 36 NOTES...
Page 77: ......
Page 78: ...System Maintenance Manual NEC Unified Solutions Inc Issue 1 0...