0DH : Bottom left selected (9 screens)  
0EH : Bottom middle selected (9 screens)  
0FH : Bottom right selected (9 screens) 

DATA02 (DISP MODE) 

00H : SPLIT  
01H : BLANKING 

 

11.MULTI MODE Request 
Function 

External control apparatus can know the MULTI MODE information on a plasma monitor. 

Transmission Data 

1FH 80H 60H 3BH 00H CKS 

ACK 

7FH 80H 60H 3BH 02H DATA00 DATA01 DATA02 CKS 
DATA00 (SCREEN DIVIDER SETTING) 

01H : Single mode  
02H : Multi mode 1 screens  
03H : Multi mode 4 screens  
04H : Multi mode 9 screens

         

 

DATA01 (POSITION OF DIVIDE) 

01H : Upper left selected (4 screens)  
02H : Upper right selected (4 screens)  
03H : Lower right selected (4 screens)  
04H : Lower left selected (4 screens)  
07H : Top left selected (9 screens)  
08H : Top middle selected (9 screens)  
09H : Top right selected (9 screens)  
0AH : Middle left selected (9 screens)  
0BH : Middle center selected (9 screens)  
0CH : Middle right selected (9 screens)  
0DH : Bottom left selected (9 screens)  
0EH : Bottom middle selected (9 screens)  
0FH : Bottom right selected (9 screens) 

DATA02 (DISP MODE) 

00H : SPLIT  
01H : BRANKING 

 

12.AUTO ID SET START 
Function 

External control apparatus sets up ID automatically to two or more plasma monitors. 

Transmission Data 

5FH 80H 60H F0H 01H DATA00 CKS 
DATA00   00H~FFH: ID of a master

*1

 is set up. 

 
*: when you use it by the multi-system, please remove the link input of a master

*1

.

 

 

*1: “Master” means the 1st set of PDP at the time of cable connection at the time of AUTO ID execution.   
 

13.PLE LINK 
Function 

External control apparatus sets up equally PLE between two or more plasma monitors. 

Transmission Data 

DFH 80H 60H F1H 03H DATA00 to DATA02 CKS 
DATA00  00H:PLE LINK ON 

01H:PLE LINK OFF  

DATA01   FFH  
DATA02   FFH 

 

Summary of Contents for PlasmaSync 84VM5

Page 1: ...84VM5 System Weight 319 2 lbs Color Correction NEC CCF Capsulated Color Filter 42VP5 42VM5 Display Weight 61 8 lbs Quad Mount Wt 72 lbs Notes This document is intended to be used as a reference guide...

Page 2: ...tallation Guide using four 42VM5 or 42VP5 Plasma Displays also a reference for optional Quad Mount used with 42VM5 or 42VP5 v1 3 www necvisualsystems com Page 2 of 14 System Dimensions Dimensions are...

Page 3: ...a reference for optional Quad Mount used with 42VM5 or 42VP5 v1 3 www necvisualsystems com Page 3 of 14 System Ventilation Requirements Dimensions below show minimum requirements for ventilation Wall...

Page 4: ...Visual Systems 84VP5 84VM5 Installation Guide using four 42VM5 or 42VP5 Plasma Displays also a reference for optional Quad Mount used with 42VM5 or 42VP5 v1 3 www necvisualsystems com Page 4 of 14 Qua...

Page 5: ...our 42VM5 or 42VP5 Plasma Displays also a reference for optional Quad Mount used with 42VM5 or 42VP5 v1 3 www necvisualsystems com Page 5 of 14 Mounting Points for Quad Mount Dimensions are in inches...

Page 6: ...nd 8 CTS Clear to send 9 No Connection 2 Connector on the external equipment side Serial port RS 232C connector See the specifications of the equipment that is to be connected for the type of connecto...

Page 7: ...and unit ID 2 are numbers used to identify the equipment that is to be connected 60H is used for the plasma monitor and 80H is used for external control equipment such as a personal computer Unit ID 1...

Page 8: ...60 4E 00 CD In ID 5 the value of ID 1 4 is set up 9D 84 60 4E 00 CF The example of a change in the single mode of a 4th page multi system configuration and the multi mode is shown below ID of the set...

Page 9: ...ed off 3FH 60H 80H 4FH 00H CKS 03 Input Switch Change Function The external control equipment switches the input of the plasma monitor Transmission Data DFH 80H 60H 47H 01H DATA00 CKS DATA00 Input Sel...

Page 10: ...CKS DATA00 01H NORMAL 02H THEATER1 03H THEATER2 04H Default 07 SCREEN MODE Select Function The external control equipment switches the screen mode of the plasma monitor Transmission Data DFH 80H 60H 5...

Page 11: ...selected 4 screens 02H Upper right selected 4 screens 03H Lower right selected 4 screens 04H Lower left selected 4 screens 07H Top left selected 9 screens 08H Top middle selected 9 screens 09H Top ri...

Page 12: ...ected 4 screens 04H Lower left selected 4 screens 07H Top left selected 9 screens 08H Top middle selected 9 screens 09H Top right selected 9 screens 0AH Middle left selected 9 screens 0BH Middle cente...

Page 13: ...FFH 1 Master means the 1st set of PDP at the time of cable connection at the time of AUTO ID execution 14 VIDEO WALL SETTING Function External control apparatus sets 4screens or 9screens as a video wa...

Page 14: ...ide using four 42VM5 or 42VP5 Plasma Displays also a reference for optional Quad Mount used with 42VM5 or 42VP5 v1 3 www necvisualsystems com Page 14 of 14 Bit2 Power Status 0 POWER ON 1 POWER OFF STA...

Reviews: