NEC
Solutions
(America),
Inc.
Visual Systems
84VP5/84VM5 Installation Guide
(using four 42VM5 or 42VP5 Plasma Displays)
(also a reference for optional Quad Mount used with 42VM5 or 42VP5)
v1.3
www.necvisualsystems.com
Page 12 of 14
0DH : Bottom left selected (9 screens)
0EH : Bottom middle selected (9 screens)
0FH : Bottom right selected (9 screens)
DATA02 (DISP MODE)
00H : SPLIT
01H : BLANKING
11.MULTI MODE Request
Function
External control apparatus can know the MULTI MODE information on a plasma monitor.
Transmission Data
1FH 80H 60H 3BH 00H CKS
ACK
7FH 80H 60H 3BH 02H DATA00 DATA01 DATA02 CKS
DATA00 (SCREEN DIVIDER SETTING)
01H : Single mode
02H : Multi mode 1 screens
03H : Multi mode 4 screens
04H : Multi mode 9 screens
DATA01 (POSITION OF DIVIDE)
01H : Upper left selected (4 screens)
02H : Upper right selected (4 screens)
03H : Lower right selected (4 screens)
04H : Lower left selected (4 screens)
07H : Top left selected (9 screens)
08H : Top middle selected (9 screens)
09H : Top right selected (9 screens)
0AH : Middle left selected (9 screens)
0BH : Middle center selected (9 screens)
0CH : Middle right selected (9 screens)
0DH : Bottom left selected (9 screens)
0EH : Bottom middle selected (9 screens)
0FH : Bottom right selected (9 screens)
DATA02 (DISP MODE)
00H : SPLIT
01H : BRANKING
12.AUTO ID SET START
Function
External control apparatus sets up ID automatically to two or more plasma monitors.
Transmission Data
5FH 80H 60H F0H 01H DATA00 CKS
DATA00 00H~FFH: ID of a master
*1
is set up.
*: when you use it by the multi-system, please remove the link input of a master
*1
.
*1: “Master” means the 1st set of PDP at the time of cable connection at the time of AUTO ID execution.
13.PLE LINK
Function
External control apparatus sets up equally PLE between two or more plasma monitors.
Transmission Data
DFH 80H 60H F1H 03H DATA00 to DATA02 CKS
DATA00 00H:PLE LINK ON
01H:PLE LINK OFF
DATA01 FFH
DATA02 FFH