background image

 

                         NEC 

Solutions 

(America), 

Inc.

 

    

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Visual Systems 

84VP5/84VM5 Installation Guide 

(using four 42VM5 or 42VP5 Plasma Displays) 

(also a reference for optional Quad Mount used with 42VM5 or 42VP5)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

v1.3

 

www.necvisualsystems.com 

 

 

Page 10 of 14 

 

ACK 

 

3FH   60H   80H   3FH   00H   CKS 

 

06. PICTURE MODE Select 
Function 

 

The external control equipment sets the picture mode of the plasma monitor. 

Transmission Data 

 

DFH   80H   60H   0AH   01H   DATA00   CKS 

 

DATA00:  01H : NORMAL 

 

 

 

 

02H : THEATER1(It cannot choose in the still picture input of a personal computer.) 

 

 

 

 

03H : THEATER2(It cannot choose in the still picture input of a personal computer.) 

    04H 

Default 

ACK 

 

7FH   60H   80H   0AH  01H  

DATA00   CKS 

 

DATA00:  01H : NORMAL 

 

 

 

 

02H : THEATER1 

 

 

 

 

03H : THEATER2 

    04H 

Default 

 

07.SCREEN MODE Select 
Function 

 

The external control equipment switches the screen mode of the plasma monitor. 

Transmission Data 

 

DFH   80H   60H   51H   01H   DATA00   CKS 

 

DATA00  02H : STADIUM 

 

 

 

 

03H : ZOOM 

 

 

 

 

04H : NORMAL 

    05H 

FULL 

 

 

 

 

06H : REAL 

    08H 

UNDERSCAN 

    09H 

14:9 

ACK 

 

7FH   60H   80H   51H   01H   DATA00   CKS 

 

DATA00  02H : STADIUM 

 

 

 

 

03H : ZOOM 

 

 

 

 

04H : NORMAL 

    05H 

FULL 

 

 

 

 

06H : REAL 

    08H 

UNDERSCAN 

    09H 

14:9 

 

08. AUTO PICTURE Select  
Function 

 

The external control equipment switches on or off the AUTO PICTURE of the plasma monitor. 

Transmission Data 

 

DFH   80H   60H   7FH   03H   DATA00   DATA01  DATA02  CKS 

 

DATA00 : USER PICTURE Gain Flag     03H 

 

DATA01 : AUTO PICTURE Select Flag   09H 

 

DATA02   00H : ON 

 

 

 

 

01H : OFF 

ACK 

 

7FH   60H   80H   7FH   03H   DATA00   DATA01  DATA02  CKS 

 

DATA00 : USER PICTURE Gain Flag     

03H 

 

DATA01 : AUTO PICTURE Select Flag   09H 

 

DATA02   00H : ON 

 

 

 

 

01H : OFF 

 
 

Summary of Contents for PlasmaSync 84VM5

Page 1: ...84VM5 System Weight 319 2 lbs Color Correction NEC CCF Capsulated Color Filter 42VP5 42VM5 Display Weight 61 8 lbs Quad Mount Wt 72 lbs Notes This document is intended to be used as a reference guide...

Page 2: ...tallation Guide using four 42VM5 or 42VP5 Plasma Displays also a reference for optional Quad Mount used with 42VM5 or 42VP5 v1 3 www necvisualsystems com Page 2 of 14 System Dimensions Dimensions are...

Page 3: ...a reference for optional Quad Mount used with 42VM5 or 42VP5 v1 3 www necvisualsystems com Page 3 of 14 System Ventilation Requirements Dimensions below show minimum requirements for ventilation Wall...

Page 4: ...Visual Systems 84VP5 84VM5 Installation Guide using four 42VM5 or 42VP5 Plasma Displays also a reference for optional Quad Mount used with 42VM5 or 42VP5 v1 3 www necvisualsystems com Page 4 of 14 Qua...

Page 5: ...our 42VM5 or 42VP5 Plasma Displays also a reference for optional Quad Mount used with 42VM5 or 42VP5 v1 3 www necvisualsystems com Page 5 of 14 Mounting Points for Quad Mount Dimensions are in inches...

Page 6: ...nd 8 CTS Clear to send 9 No Connection 2 Connector on the external equipment side Serial port RS 232C connector See the specifications of the equipment that is to be connected for the type of connecto...

Page 7: ...and unit ID 2 are numbers used to identify the equipment that is to be connected 60H is used for the plasma monitor and 80H is used for external control equipment such as a personal computer Unit ID 1...

Page 8: ...60 4E 00 CD In ID 5 the value of ID 1 4 is set up 9D 84 60 4E 00 CF The example of a change in the single mode of a 4th page multi system configuration and the multi mode is shown below ID of the set...

Page 9: ...ed off 3FH 60H 80H 4FH 00H CKS 03 Input Switch Change Function The external control equipment switches the input of the plasma monitor Transmission Data DFH 80H 60H 47H 01H DATA00 CKS DATA00 Input Sel...

Page 10: ...CKS DATA00 01H NORMAL 02H THEATER1 03H THEATER2 04H Default 07 SCREEN MODE Select Function The external control equipment switches the screen mode of the plasma monitor Transmission Data DFH 80H 60H 5...

Page 11: ...selected 4 screens 02H Upper right selected 4 screens 03H Lower right selected 4 screens 04H Lower left selected 4 screens 07H Top left selected 9 screens 08H Top middle selected 9 screens 09H Top ri...

Page 12: ...ected 4 screens 04H Lower left selected 4 screens 07H Top left selected 9 screens 08H Top middle selected 9 screens 09H Top right selected 9 screens 0AH Middle left selected 9 screens 0BH Middle cente...

Page 13: ...FFH 1 Master means the 1st set of PDP at the time of cable connection at the time of AUTO ID execution 14 VIDEO WALL SETTING Function External control apparatus sets 4screens or 9screens as a video wa...

Page 14: ...ide using four 42VM5 or 42VP5 Plasma Displays also a reference for optional Quad Mount used with 42VM5 or 42VP5 v1 3 www necvisualsystems com Page 14 of 14 Bit2 Power Status 0 POWER ON 1 POWER OFF STA...

Reviews: