Check Sum Example  

 

2) Error Processing 
• When the communication interval is vacant for more than 4 ms, thereafter a received Command 1 will be recognized. If, at 
this time, meaningful data cannot be recognized, that data will not be recognized (as valid data). 
• An ACK will not be returned unless the receive data error, the check sum error, and the receive data are all taken in. 
 
The control method of the set by Set ID 
When controlling two or more sets of plasma monitors, if the command using Set ID is used, it will become controllable 
individually. 
The example of the POWER ON command to the plasma monitor which set ID as "5" is shown below. 
 
It is not based on ID but is the POWER ON command to all sets. 
 

 

9F  80  60  4E  00  CD 

 
In ID= "5", the value of ID-1=4 is set up. 
 

 

9D  84  60  4E  00  CF 

 
The example of a change in the single mode of a 4th page multi-system configuration and the multi-mode is shown below.  
ID of the set used as a master(etc PC) is set to 50, and it assumes that ID is shaken by AUTO ID to each set. ID shaken at 
each set is as follows. 
Upper left set (master) ID = 50 = 32h 
Upper right set ID = 51 = 33h 
Lower right set ID = 52 = 34h 
Lower left set ID = 53 = 35h 
 
Transmission Data 
 

DD  81  63  03  03  03  01  00  CB 

 

DD  82  63  03  03  03  02  00  CD 

 

DD  83  63  03  03  03  03  00  CF 

 

DD  84  63  03  03  03  04  00  D1 

 
Transmission of the above command performs a 4th page multi SPLIT display. 
Moreover, the following commands are published in order to change a 4th page multi-display into a single mode display. 
 

DF  80  60  03  03  01  01  00  C7 

All sets become a single mode display by the above-mentioned command.  
Since this command does not specify Set ID, all sets execute it. 
 
*:Control by ID may not be able to be performed depending on connection with external control apparatus. 
 
 
 
 
 
 
 
 
 

 Total 208H  

 

DFH 

 80H  60H  47H  01H

01H

08H

Command1  Unit ID1  

Unit ID2  

Command2  Data Length  Data 

 

Check Sum 

Summary of Contents for PlasmaSync 84VM5

Page 1: ...84VM5 System Weight 319 2 lbs Color Correction NEC CCF Capsulated Color Filter 42VP5 42VM5 Display Weight 61 8 lbs Quad Mount Wt 72 lbs Notes This document is intended to be used as a reference guide...

Page 2: ...tallation Guide using four 42VM5 or 42VP5 Plasma Displays also a reference for optional Quad Mount used with 42VM5 or 42VP5 v1 3 www necvisualsystems com Page 2 of 14 System Dimensions Dimensions are...

Page 3: ...a reference for optional Quad Mount used with 42VM5 or 42VP5 v1 3 www necvisualsystems com Page 3 of 14 System Ventilation Requirements Dimensions below show minimum requirements for ventilation Wall...

Page 4: ...Visual Systems 84VP5 84VM5 Installation Guide using four 42VM5 or 42VP5 Plasma Displays also a reference for optional Quad Mount used with 42VM5 or 42VP5 v1 3 www necvisualsystems com Page 4 of 14 Qua...

Page 5: ...our 42VM5 or 42VP5 Plasma Displays also a reference for optional Quad Mount used with 42VM5 or 42VP5 v1 3 www necvisualsystems com Page 5 of 14 Mounting Points for Quad Mount Dimensions are in inches...

Page 6: ...nd 8 CTS Clear to send 9 No Connection 2 Connector on the external equipment side Serial port RS 232C connector See the specifications of the equipment that is to be connected for the type of connecto...

Page 7: ...and unit ID 2 are numbers used to identify the equipment that is to be connected 60H is used for the plasma monitor and 80H is used for external control equipment such as a personal computer Unit ID 1...

Page 8: ...60 4E 00 CD In ID 5 the value of ID 1 4 is set up 9D 84 60 4E 00 CF The example of a change in the single mode of a 4th page multi system configuration and the multi mode is shown below ID of the set...

Page 9: ...ed off 3FH 60H 80H 4FH 00H CKS 03 Input Switch Change Function The external control equipment switches the input of the plasma monitor Transmission Data DFH 80H 60H 47H 01H DATA00 CKS DATA00 Input Sel...

Page 10: ...CKS DATA00 01H NORMAL 02H THEATER1 03H THEATER2 04H Default 07 SCREEN MODE Select Function The external control equipment switches the screen mode of the plasma monitor Transmission Data DFH 80H 60H 5...

Page 11: ...selected 4 screens 02H Upper right selected 4 screens 03H Lower right selected 4 screens 04H Lower left selected 4 screens 07H Top left selected 9 screens 08H Top middle selected 9 screens 09H Top ri...

Page 12: ...ected 4 screens 04H Lower left selected 4 screens 07H Top left selected 9 screens 08H Top middle selected 9 screens 09H Top right selected 9 screens 0AH Middle left selected 9 screens 0BH Middle cente...

Page 13: ...FFH 1 Master means the 1st set of PDP at the time of cable connection at the time of AUTO ID execution 14 VIDEO WALL SETTING Function External control apparatus sets 4screens or 9screens as a video wa...

Page 14: ...ide using four 42VM5 or 42VP5 Plasma Displays also a reference for optional Quad Mount used with 42VM5 or 42VP5 v1 3 www necvisualsystems com Page 14 of 14 Bit2 Power Status 0 POWER ON 1 POWER OFF STA...

Reviews: