461
CHAPTER 19 SERIAL INTERFACE CHANNEL 2
19.4.3 3-wire serial I/O mode
The 3-wire serial I/O mode is useful for connection of peripheral I/Os and display controllers, etc., which incorporate
a conventional synchronous clocked serial interface, such as the 75X/XL Series, 78K Series, 17K Series, etc.
Communication is performed using three lines: the serial clock (SCK2), serial output (SO2), and serial input (SI2).
(1) Register setting
The 3-wire serial I/O mode is set with the serial operating mode register 2 (CSIM2) and serial bus interface
control register (SBIC).
(a) Serial operating mode register 2 (CSIM2)
CSIM2 is set with a 1-bit or 8-bit memory manipulation instruction.
RESET input sets CSIM2 to 00H.
Caution
Ensure that bits 0 and 3 to 6 are set to 0.
6
5
4
3
2
1
0
7
Symbol
CSIM2 CSIE2
0
0
0
0
CSIM
22
CSCK
0
CSCK
0
1
Serial Operating Mode Selection
UART mode
3-wire serial I/O mode
CSIM22
0
1
First Bit Specification
MSB
LSB
CSIE2
0
1
Operation Control in 3-wire Serial I/O Mode
Operation stopped
Operation enabled
FF72H 00H R/W