218
µPD750008 USER'S MANUAL
Figure 7-1. Standby Mode Release Operation (2/2)
(c) Release of the HALT mode by RESET signal
(d) Release of the HALT mode by the occurrence of an interrupt
Note The following two wait times can be selected by a mask option:
2
17
/f
X
(21.8 ms at 6.00 MHz, 31.3 ms at 4.19 MHz)
2
15
/f
X
(5.46 ms at 6.00 MHz, 7.81 ms at 4.19 MHz)
However, the µPD75P0016 dose not have a mask option and its wait time is fixed to 2
15
/f
X
.
Remark The dashed line indicates the case where the interrupt request that releases the standby mode
is accepted.
When the STOP mode is released by the occurrence of an interrupt, a wait time is determined by the basic
interval timer mode register (BTM). (See Table 7-2.)
A time required for stable oscillation varies with the type of resonator used and the supply voltage at the
time of STOP mode release. Accordingly, a wait time is to be selected according to each application, and
BTM is to be set before the STOP mode is set.
*
HALT instruction
Standby
release
signal
Clock
HALT mode
Operating mode
Oscillation
Operating mode
HALT instruction
RESET
signal
Clock
Operating
mode
HALT mode
Operating
mode
Oscillation
Wait
Note
Summary of Contents for PD750004
Page 8: ... MEMO ...
Page 20: ... xii MEMO ...
Page 234: ...214 µPD750008 USER S MANUAL MEMO ...
Page 244: ...224 µPD750008 USER S MANUAL MEMO ...
Page 248: ...228 µPD750008 USER S MANUAL MEMO ...
Page 254: ...234 µPD75008 USER S MANUAL MEMO ...
Page 328: ...308 µPD750008 USER S MANUAL MEMO ...
Page 330: ...310 µPD750008 USER S MANUAL MEMO ...
Page 342: ...322 µPD750008 USER S MANUAL MEMO ...