- 82 -
6> Execute
“
hbacmd SetPersistentBinding
”
for this product and set a persistent binding between the
WWPN address of tape storage/ disk array and the SCSI Bus target. If binding target device is
more than one, repeat executing
“
hbacmd SetPersistentBinding
”
for the same product.
Use a value
P
for the parameter of both <Scope> and <BindType>. Use the same value for
<SCSI
Bus>, <SCSI Target> and <ID(Port WWN)> checked in item5>.
Refer to next item
“
Hbacmd command
”
for more information of
"hbacmd SetPersistentBinding"
C:
\
Program Files
\
Emulex
\
Util
\
OCManager>hbacmd setpersistentbinding 10:00:00:90:f
a:02:11:28 P P 21:00:00:16:97:12:24:46 0 0
Set Persistent Binding for 10:00:00:90:fa:02:11:28 P P 21:00:00:16:97:12:24:46 0
0
Binding configured but not active. Reboot required.
7> Execute
“
hbacmd persistentbinding
”
with parameter <Source> =
“
C
”
for this product that is set
persistent binding and confirm the binding configurations (SCSI Bus Number, SCSI Target num and
Port WWN) are correct.
C:
\
Program Files
\
Emulex
\
Util
\
OCManager>hbacmd persistentbinding 10:00:00:90:fa:0
2:11:28 c
Persistent Binding for 10:00:00:90:fa:02:11:28
Bind Type : WWPN
FCP ID : 0
SCSI Bus Number: 0
SCSI Target Num: 0
Node WWN : 00:00:00:00:00:00:00:00
Port WWN : 21:00:00:16:97:12:24:46
OS Device Name :
If there are any wrong configurations, remove that configurations by
executing "hbacmd RemovePersistentBinding" and set persistent bindings
again.
If you want to remove all configuration of the one product, you can remove
all configuration for this product by executing
"hbacmd RemoveAllPersistentBinding".
Refer to next item
“
Hbacmd command
”
for more information of
“
RemovePersistentBinding
”
and
“
RemovePersistentBinding
”
8> Repeat the same step for the remaining this product, to set persistent bindings.
9> Reboot the system and log in it using the Administrator.
Tips
Tips
Port WWN of 5.
SCSI Bus/Target of 5
.