background image

 

*856-128776-004-00X*

 

N8403-065F 

N8403-067F 

Dual Port 10GBASE Adapter 

 

1st.  Edition 

 
Congratulations  for  your  purchase  of  the  N8403-065F/N8403-067F  Dual  Port 
10GBASE Adapter. 
The  User’s  Guide  is  intended  to  allow  you  to  install  and  use  the 
N8403-065F/N8403-067F Dual Port 10GBASE Adapter (called the card hereafter) 
correctly  and  safely.  Read  this  manual  thoroughly  before  handling  the  card.  In 
addition, refer to this guide whenever you want to know how to use the card or 
some malfunction occurs. Always keep this guide at hand so that you can see it 
when necessary. 
For the CPU b

lade in which the card is installed, refer to the User’s Guide of the 

CPU  Blade.  Read  "Notes  on  Use"  and  "Safety  Indications"  carefully  before 
handling the card. 

 

Contents 

Item 

Qty.  Notes 

Dual Port 10GBASE 

Adapter 

Type I mezzanine card 

User

’s Guide 

This Guide 

Screw 

Screws to secure the card to CPU blade. 

 

User’s

Guide

Dual Port 10GBASE Adapter

Screw

N8403-065F(Or N8403-067F)

x3

 

 
 
 
 
Notes: 

1. 

No part of this manual may be reproduced in any form without the prior 
written permission of NEC Corporation. 

2. 

The contents of this manual may be revised without prior notice. 

3. 

The contents of this manual shall not be copied or altered without the prior 
written permission of NEC Corporation. 

4. 

All efforts have been made to ensure the accuracy of all information in this 
manual. If you notice any part unclear, incorrect, or omitted in this manual, 
contact the sales agent where you purchased this product. 

5. 

NEC assumes no liability arising from the use of this product, nor any liability 
for incidental or consequential damages arising from the use of this manual 
regardless of item (4). 

6. 

If you find any missing pages or pages out of order in this manual, please 
contact your dealer for a replacement. 

 

NEC Corporation 2012 

No  part  of  this  guide  may  be  reproduced  or  changed  in  any  form  without  prior  written 

permission of NEC Corporation. 

 

Disposing of your used product 

In the European Union 

 

EU-wide legislation as implemented in each Member State requires that used 
electrical  and  electronic  products  carrying  the  mark  (left) must  be  disposed  of 
separately from normal household waste. This includes workstation or electrical 
accessories. When you dispose of such products, please follow the guidance of 
your  local  authority  or  ask  the  shop  where  you  purchased  the  product,  or  if 
applicable, follow applicable legislation or agreement you may have. The mark 
on electrical and electronic products only applies to the current European Union 
Member States. 

Outside the European Union 

If you wish to dispose of used electrical and electronic products outside the European Union, 
please contact your local authority and ask for the correct method of disposal. 

China RoHS 

x: 表示

有毒有害物

至少在

部件的某一均

材料中的含量超出SJ/T11363-

2006

定的限量要求

二苯

(PBDE) 

六价

(Cr6+) 


(Hg) 

o: 表示

有毒有害物

部件所有均

材料中的含量均在SJ/T11363-2006

定的限量要求以下

印刷

(PBB) 

(Cd)

(Pb) 

有毒有害物

或元素

部件
名称

 

Turkish RoHS information relevant for Turkish market 

EEE Yönetmeliğine Uygundur 

Vietnam RoHS information relevant for Vietnam market 

Complying with 

CIRCULAR,No.30/2011/TT-BCT

Hanoi,August 10 2011

,   

Temporary  regulations  on  content  limit  for  certain  hazardous  substances  in 
electrical products” 

Trademarks 

EXPRESSBUILDER is a trademark of NEC Corporation. 
Broadcom is among the trademarks of Broadcom Corporation and/or its affiliates in the United 
States, certain other countries, and/or the EU.   
PCI-EXPRESS is a trademark of PCI-SIG. Any other trademarks or trade names mentioned 
are the property of their respective owners.   
Windows  is  a  registered  trademark  of  Microsoft  Corporation  in  the  United  States  and  other 
countries. 
Linux is a registered trademark of Linus Torvalds. 

 

 

Keep this Startup Guide at hand for quick reference at anytime 
necessary.Be sure to read this section carefully.

 

 

 

Precautions for Use 

 

-Be sure to read this section - 

The following includes information necessary for proper and safe operation of the 
product.

   

Safety Indication 

Follow the instructions in this Startup Guide for your safety to use this product. 

The server contains components with possible danger, hazards that may cause by ignoring 

warnings, and preventive actions against such hazards. The 

words “WARNING” and 

“CAUTION” are used to indicate the degrees of danger. These terms are defined as follows: 

 

Indicates the presence of a hazard that may result in death 
or serious personal injury if the instruction is ignored.

   

 

Indicates the presence of a hazard that may cause minor 
personal injury, including burns, or property damage if the 
instruction is ignored.

 

This guide uses the following three types of symbols to give indications and 
precautions against a danger. They are defined as follows:

 

 

Attention

 

This symbol indicates the 
presence of a hazard if the 
instruction is ignored. An image in 
the symbol illustrates the hazard 
type. 

Example

 

 

  (Electric hazard)

 

 

Prohibited 
action

 

This symbol indicates prohibited 
actions. An image in the symbol 
illustrates a particular prohibited 
action. 

Example

 

(Do not disassemble)

 

 

Mandatory 
action

 

This symbol indicates mandatory 
actions. An image in the symbol 
illustrates a mandatory action to 
avoid a particular hazard. 

Example

 

(Unplug)

 

 

Do not plug the power cord in a 

nonconforming outlet

Use a wall outlet with specified voltage and power type.
Otherwise, ther is a risk of a fire or current leakage.

Symbol to draw attention

Description of a danger

Term indication a degree of danger

 

Symbols Used in This Startup Guide 

 

Attentions 

 

Indicates  a  risk  of  an  electric 
shock. 

 

Indicates  a  risk  of  a  fire  or 
fumes. 

 

Indicates a general precaution 
or warning that cannot be 
specifically identified. 

 

 

Prohibited actions

 

 

Do not disassemble, repair, or 
modify this product. 
Otherwise, there is a risk of an 
electric shock or fire. 

 

Indicates a general prohibited 
action. 

Mandatory actions

 

 

Unplug the power cord of the 
server. Otherwise, there is a 
risk of an electric shock or fire. 

 

 

 

Precautions for Safety 

General Precautions 

 

 

Do not use this product for services where critical high 
availability may directly affect human lives.

 

This product is not intended to be used with or control facilities or devices 
concerning human lives, including medical devices, nuclear facilities and 
devices,  aeronautics  and  space  devices,  transportation  facilities  and 
devices; and facilities and devices requiring high reliability. NEC assumes 
no liability for any accident resulting in personal injury, death, or property 
damage if this product has been used in the above conditions.

 

 

 

 

Do not disassemble, repair, or alter this product.

 

Never  attempt  to  disassemble,  repair,  or  alter  this  product  on  any 
occasion  other  than  described  in  this  manual.  Failure  to  follow  this 
instruction may cause an electric shock or fire as well as malfunctions of 
this product. 

 

 

Do not use this product if any smoke, odor, or noise is 
present.

 

If  smoke,  odor,  or  noise  is  present,  immediately  turn  off  the 
POWER/SLEEP switch and disconnect the power plug from the outlet, 
then contact your sales agent. Using this product in such conditions may 
cause a fire. 

 

 

 

Avoid installation in extreme temperature conditions.

 

Immediately after the server is powered off, its internal components such 
as hard disks are very hot. Leave the server until its internal components 
fully cool down before installing/removing any component.

 

 

Connect firmly.

 

Please  connect  the  product  to  the  computer  firmly.  A  loose  connection 
can cause a contact failure and can lead to smoke or fire.

 

 

Insert the power plug into the outlet as far as it goes.

 

Heat  generation  resulting  from  a  halfway  inserted  power  plug/cable 
(imperfect  contact)  may  cause  a  fire.  Heat  will  also  be  generated  if 
condensation  is  formed  on  dusty  blades  of  the  halfway  inserted  plug, 
increasing the possibility of fire.

 

 

 

 

Do not use any unauthorized interface cable.

 

Use  only  the  interface  cable  that  comes  with  this  product.  Use  of  an 
unauthorized interface cable may cause a fire when the electric current 
exceeds the rated flow. Also, observe the following to prevent an electric 
shock or fire caused by a damaged cord. 

Do not use any damaged cable. (Replace a damaged cable with a 
new  one  of  the  same  specifications.  Ask  your  sales  agent  for 
replacement.) 

Do not step the cable. 

Do not place any object on the cable. 

Do not alter, modify, or repair the cable.

 

 

 

Do  not  use  or  store  this  product  in  corrosive 
environment.

 

Avoid the usage or storage of this product in an environment which may 
be exposed to corrosive gases, such as those including but not limited to: 
sulfur  dioxide,  hydrogen  sulfide,  nitrogen  dioxide,  chlorine,  ammonia 
and/or ozone. Avoid installing this product in a dusty environment or one 
that  may  be  exposed  to  corrosive  materials  such  as  sodium  chloride 
and/or sulfur. Avoid installing this product in an environment which may 
have  excessive  metal  flakes  or  conductive  particles  in  the  air.  Such 
environments  may  cause  corrosion  or  short  circuits  within  this  product, 
resulting in not only damage to this product, but may even lead to be a 
fire hazard. If there are any concerns regarding the environment at the 
planned site of installation or storage, please contact your sales agent.

 

 

Summary of Contents for N8403-065

Page 1: ...PCI SIG の登録商標です Windows は米国 Microsoft Corporation の米国およびその他の国における登録商標です Linux は Linus Torvalds 氏の日本およびその他の国における登録商標または商標です 本文中には マークは明記していません 本書は必要なときすぐに参照できるよう お手元に置いておくようにしてください 使用上のご注意 を必ずお読みください 使用上のご注意 必ずお読みください 本製品を安全に正しくご使用になるために必要な情報が記載されています 本文中の名称については本書の 外観および各部の名称 の項をご参照ください 本製品を安全にお使い頂くために 本書の指示に従って操作してください 本書には装置のどこが危険でどのような危険に遭うおそれがあるか どうすれば危険を避けられるかなどについて説明されています 本書では危険の程度を表す言葉として ...

Page 2: ...を促進する成分 塩化ナトリウムや硫黄など や導電性の金属などが含まれてい る環境へも設置しないでください 装置内部のプリント板が腐食し 故障および発煙 発火の原因となるおそれがあります もしご使用の環境で上記の疑いがある場合は 販売店または保守サービス会社にご相談ください 使用上のご注意 本製品を正しく動作させるために 本製品を使用するときに注意していただきたいことを次に示します これらの注意を無視して 本製品を使用した場合 資産 データや その他の装置 が破壊されるおそれがありますので必ずお守りください 本製品は大変静電気に弱い電子部品です ブレード収納ユニットの金属フレーム部分などに触れて身体の静電気を逃が してから取り扱ってください また 本製品の端子部分や部品を素手で触ったり 直接机の上に置いたりしないでください 本製品を落としたり物にぶつけたりしないでください 誤動作や故障するお...

Page 3: ...取り付けた CPU ブレードに LAN ドライバはインストールさ れていますか また 正しくセットアップしましたか CPU ブレードのインストレーションガイドを参照して LAN ドライバ を正しくセットアップしてください 本製品がメザニン拡張スロットにしっかりと接続されていますか また スイッチモジュールにケーブルは正しく接続されていますか もう一度確認し 接続されていない場合は しっかりと接続しなおして ください 本製品を実装した CPU ブレードのメザニン拡張スロット番号 ブレード 収納ユニットのCPUブレードの搭載位置やスイッチモジュールの搭載位 置は対応が取れていますか CPU ブレード ブレード収納ユニット スイッチモジュールのユーザー ズガイドを参照して 適切な搭載位置であることを確認してください N8403 065 10GBASE 接続ボード 2ch N8403 067 10...

Page 4: ...a hazard that maycause minor personal injury including burns or propertydamage if the instruction is ignored This guide uses the following three types of symbols to give indications and precautions against a danger They are defined as follows Attention This symbol indicates the presence of a hazard if the instruction is ignored An image in the symbol illustrates the hazard type Example Electric ha...

Page 5: ...iSCSI offload model See also MAC address It describes about the numbering rules of the MAC address Screw Use these screws to secure the card to spacer of the CPU blade IMPORTANT Depending on the CPU blade equipped with the product the numbers of screws used are different Setup Step1 Attach this product to a CPU blade Step2 Insert the CPU Blade to a Blade Enclosure Unit Step3 Install LAN driver to ...

Page 6: ...d cables connected firmly Firmly connect them once again Are the mezzanine slot to which the card is installed location of the slot to which the CPU blade is installed and the installation location of switch module corresponding to the card such as 10Gb Pass Through Card is installed appropriate Refer to the manuals of the CPU Blade Blade Enclosure installed switch module NOTE If the same error pe...

Reviews: