25
6. Notes
Read the following notes thoroughly before using the BBU.
6-1. Notes on Installation
Do not put the BBU on a metallic plate including the chassis of the server. Do not hold
the BBU with wet hands. If you do not follow these directions, the battery may be
short-circuited.
To install the BBU in the server, a single PCI slot of the server must be used. Before
starting the installation, make sure that at least an unused PCI slot remains unused.
6-2. Notes on Operation
The life of the battery pack used for the BBU is about 2 years, which may vary a little
depending on the use environment and environmental conditions. Replace the battery
pack with a new one after about two years from the installation. For the replacement,
contact your service representative.
To manage the states of the BBU properly, install the disk Array Controller
Management Utility "WebPAM." WebPAM allows you to detect errors and check the
states of the BBU (including voltage and temperature)
After the installation of the BBU, the following warning log is registered in event logs
including the system and WebPAM logs every boot of OS. The log indicates that the
BBU can be recognized during boot of OS and does not show the occurrence of an
error.
Battery becomes normal, Parameter1=0(0x0), Parameter2=0(0x0)