GETTING STARTED
After mounting the LED Wall, check all cable connections and ensure they are connected
according to 15.1 Cable Plans. The cable plans also include the connection between a computer
and the NovaStar Controller.
7.1
Info on the Connection Setup
Warning!
Only trained personnel, such as electricians or NEC personnel, may
connect the internal power supply to mains power supply.
Power input for the LED Wall is provided by connecting the Power bar to the electric power system
of the building. Ensure there is a possibility to switch the power for the LED Wall on and off.
Data input is provided by connecting the Power bar to a NovaStar Controller. The NovaStar
Controller is connected to a content computer, which provides the content data, and to a service
computer, which provides data about how the content is displayed on the screen.
Notice
The NovaStar Controller is no product of NEC DISPLAY SOLUTIONS.
For detailed information on the NovaStar Controller, see the respective manual for
NovaStar Controller MCTRL660 PRO. Download the current version at:
https://www.novastar.tech/download/download-controller/
7.2
Install Controller Software NovaLCT
To configure and check the functions of the controller, you need to install the software NovaLCT.
The software installation package is delivered via USB flash drive.
The software allows you to perform screen configuration, brightness adjustment, calibration,
display control, monitoring, etc. To install the software, follow the steps below:
Connect the delivered USB flash drive to your computer.
Step 1)
Open the USB flash drive.
Step 2)
Navigate to the executable installation file
NovaLCT.exe
.
Step 3)
Click the
NovaLCT.exe
file to start the installation of the software.
Step 4)
Follow the instructions of the installation wizard to complete the software installation. If
Step 5)
the firewall prompt appears, allow the installation.
Notice
Deactivate the antivirus software during the installation.
Summary of Contents for LED-FA025i2-220
Page 61: ...61 Figure 78 Screen Settings for 8 8 Controller...
Page 91: ...91 Part Name AC terminal Hub For 0 9 mm only CAT cable Mask For 1 5 1 9 2 5 3 8 mm only...
Page 96: ...96 LED FA015i2 137 Data Connections 15 1 3 LED FA015i2 137 Power Connections 15 1 4...
Page 97: ...97 LED FA019i2 165 Data Connections 15 1 5 LED FA019i2 165 Power Connections 15 1 6...
Page 99: ...99 LED FA012i2 220 Data Connections 15 1 9 LED FA012i2 220 Power Connections 15 1 10...