User’s Manual U13390EJ2V0UM
36
APPENDIX B CAUTIONS ON DESIGNING TARGET SYSTEM
Figures B-1 and B-2 show the conditions when connecting the emulation probe to the conversion adapter or
conversion socket. Follow the configuration below and consider the shape of parts to be mounted on the target
system when designing a system.
Figure B-1. Distance Between In-Circuit Emulator and Conversion Socket
Conversion socket:
Conversion adapter:
In-circuit emulator
IE-78K0S-NS or IE-78K0S-NS-A
Emulation board
IE-789801-NS-EM1
CN1
170 mm
Note
Emulation probe
NP-44GB, NP-44GB-TQ,
NP-H44GB-TQ
Target system
EV-9200G-44
TGB-044SAP
Note
Distance when NP-44GB and NP-44GB-TQ are used. When NP-H44GB-TQ is used, the distance is 370
mm.
Remarks 1.
NP-44GB, NP-44GB-TQ, and NP-H44GB-TQ are products of Naito Densei Machida Mfg. Co., Ltd.
2.
TGB-044SAP is a product of TOKYO ELETECH CORPORATION.