CHAPTER 1 OVERVIEW
6
1.6
Connection between IE-703002-MC and IE-703003-MC-EM1
The procedure for connecting the IE-703002-MC and IE-703003-MC-EM1 is described below.
Caution
Connect carefully so as not to break or bend connector pins.
<1> Remove the pod cover of the IE-703002-MC.
<2> Set the PGA socket lever of the IE-703003-MC-EM1 to the OPEN position as shown in Figure 1-4 (b).
<3> Connect the IE-703003-MC-EM1 to the PGA socket at the back of the pod (refer to Figure 1-4 (c)). When
connecting, position the IE-703002-MC and IE-703003-MC-EM1 so that they are horizontal.
<4> Set the PGA socket lever of the IE-703003-MC-EM1 to the CLOSE position as shown in Figure 1-4 (b).
<5> Set the jumpers (JP1 to JP4) and switches (SW1 and SW2). Open JP1 (Remove the jumper contact. Attach
the removed jumper contact to one of the jumper pins to avoid losing them.) Set JP2 to JP4 and SW1 and
SW2 depending on the use. Short the first and second pin of JP4.
<6> Fix the IE-703003-MC-EM1 between the pod covers (upper and lower) with the plastic screws.
<7> Secure the pod cover (upper) end with nylon rivets.
Figure 1-4. Connection between IE-703002-MC and IE-703003-MC-EM1 (1/2)
(a) Overview
IE-703002-MC
IE-703003-MC-EM1
Upper cover
Nut
Washer
Lower cover
Plastic screw
Nylon revets