7-4. FACTORY MODE SETTING
7-4-1 FACTORY MODE: OFF
→
ON
1) Open the MENU(U),TAG7 - "DISPLAY MODE"(As below)
2) Press "RESET" and "
t
","
6
" switch at once.
3) A "WARNING" will be displayed, then press "PROCEED" switch once.
4) LED indicator light turn to Yellow from Green.
7-4-2 FACTORY MODE ON
→
OFF
1) When OSM MENU is displayed, press "EXIT" switch twice. Otherwise, press "EXIT" switch once.
2) A "WARNING" will be displayed, then press "EXIT" switch once.
3) LED indicator light turns to Green from Yellow.
7-5. Displaying the OSM
7-5-1 FACTORY MODE: OFF
MENU(U): Press "EXIT" or "+" , "-" , "
t
" , "
6
" , "PROCEED" once .
MENU(S): Open MENU, TAG7 "INFORMATION" - "DISPLAY MODE”, and press "RESET" and "
t
" , "
6
"
switch at once.
A warning message will be displayed, then press "PROCEED" switch.
7-5-2 FACTORY MODE: ON
MENU(U): Press "+" , "-" or "
t
","
6
" switch.
MENU(S): Press "PROCEED" switch once.
7-5-3 Self Test
When FACTORY MODE is ON, Self test is on by no signal.
When FACTORY MODE is OFF, Self test in on by power on with pushing “RESET” switch.