![background image](http://html.mh-extra.com/html/nec/fp1350-multisync-22-crt-display/fp1350-multisync-22-crt-display_service-manual_249598125.webp)
7-13
5-2. Vertical Size
5-3. Horizontal Position
Check whether the amplitude (approx. 6Vp-p~10Vp-p) at CN-DSB pin 12
on the DEF PWB (PWE-568) varies by OSD vertical size control or not ?
•
IC501 or IC511 failure.
•
Digital control circuit failure. (see item 12)
Check whether the amplitude (approx. 6Vp-p~10Vp-p) at IC421 8 pin on
the DEF PWB (PWE-568) varies by OSD vertical size control or not ?
IC421 or its ambient circuit failure.
V OSC/DEF circuit failure. (see item 7)
Check the raster position.
Raster centering circuit failure.
•
IC501 failure.
•
Q504, Q505 or their ambient circuit failure.
•
Digital control circuit failure. (see item 12)
NG
OK
NG
OK
NG
OK
v. size max.
Approx.10Vp-p
v. saw wave
v. size min.