List of Windows Event Log
Installation Guide (Windows Server 2016)
92
Chapter 3 Appendix
ID
Source
Level
Message (Description)
Timing when an event is logged
Action
All Windows OS ”System Log”
56
Application Popup
Error
The description for Event ID 56 from source Application
Popup cannot be found. Either the component that raises
this event is not installed on your local computer or the
installation is corrupted. You can install or repair the
component on the local computer.
If the event originated on another computer, the display
information had to be saved with the event.
The following information was included with the event:
SCSI
XXXXXXXXXXXXXXXXXX
The message resource is present but the message was not
found in the message table.
* A different number replaces X depending on the
connection status of RAID controller and SAS controller.
When installing an OS, starting system,
or applying Starter Pack
When multiple RAID controller or SAS controller are loaded it is
registered, but does not affect system operation.
129
SmartDQa
Warning
Reset was issued to the device \Device\RaidPort(x).
(x is any number)
While the system is running
If this message has been registered as a log during heavy I/O,
there is no problem since the OS has succeeded in retry. Continue
using.
129
SmartPqi
Warning
Reset was issued to the device \Device\RaidPort(x).
(x is any number)
While the system is running
If this message has been registered as a log during heavy I/O,
there is no problem since the OS has succeeded in retry. Continue
using.
157
Disk
Warning
Disk x is suddenly removed.
When creating a RAID
If you create new RAID on Windows, this event can be registered,
but this does not affect the system operation.
1407
ESMCommonService
Error
This is the event which occurred between this system start-up and
the last system stop or system shutdown.
Date : YYYY-MM-DD hh:mm:ss
Event Class : 0x11
Event Code : 0x0A
Status : Critical
Description : xxxxx Connectivity status changed to xxxxx
for adapter in slot x, port x
When starting system,
or applying Standard Program Package
This event does not affect system operation.
。