![background image](http://html.mh-extra.com/html/nec/express5800-320ma/express5800-320ma_administrators-manual_250112049.webp)
Performing ftSMC Tasks
ftServer Management Console
3-13
Required Operational States for Commands
Table 3-3
presents the operational state that a device must be in to carry out the
associated command.
Table 3-3. Operational State for Associated Commands
Command
Valid States
CPU Element
Initiate BringUp
Removed, Broken, Shot, Firmware update complete,
Diagnostics passed.
Initiate BringDown
Broken, Firmware update complete, Diagnostics passed,
Duplex.
Initiate Diagnostics
Removed, Broken, Firmware update complete,
Diagnostics passed.
Set Priority
CPU element must be online and duplexed.
I/O Element
Initiate BringUp
Removed, Broken, Shot, Diagnostics passed.
Initiate BringDown
Broken, Diagnostics passed, Duplex.
Initiate Diagnostics
Removed, Broken, Diagnostics passed.