Troubleshooting 7-21
On-screen
message
Description
Action
Proc 1.05v Alm 02
1.05V voltage alarm
(lower limit) occurred on
processor.
Proc 1.05v Alm 09
1.05V voltage alarm
(upper limit) occurred on
processor.
Proc Core Alm 02
A core voltage alarm
(lower limit) was detected
in processor.
Proc Core Alm 09
A core voltage alarm
(upper limit) was detected
in processor.
1. Take one of the following measures to power
off the modular server and then on.
* Power off the modular server from OS,
then press the POWER/SLEEP switch to
power on.
* Press the POWER/SLEEP switch to power
off the modular server, then press it again
to power on.
* Issue a command from Web browser of
EXPRESSSCOPE Engine or NEC
ESMPRO Manager.
2. Power off the modular server by issuing an
OS command or press the POWER/SLEEP
switch. Take the modular server out of the
Module Enclosure, and install it again. Then,
press the POWER/SLEEP switch to turn on
the modular server.
3. Check installation status of the heat sink of
the modular server.
4. If the same error persists, contact your
service representative.
Proc Missing
No processor is installed.
Contact your service representative.
Summary of Contents for EXPRESS5800/100 SERIES N8100-1635F
Page 12: ...vi Appendix A Specifications A 1 Appendix B Using a Client Computer Which Has a CD Drive B 1 ...
Page 82: ...5 4 Installing and Using Utilities This page is intentionally left blank ...
Page 126: ...7 36 Troubleshooting When you use a remote console 6 Select a desired tool to start it ...
Page 148: ...8 14 Upgrading Your Modular Server This page is intentionally left blank ...
Page 150: ...A 2 Specifications This page is intentionally left blank ...
Page 152: ...B 2 Using a Client Computer Which Has a CD Drive This page is intentionally left blank ...