H.323 Trunk
Document Revision 1
Hardware, Installation and Maintenance Manual
4 - 3
___________________________________________________________________________________
___________________________________________________________________________________
When the user dials any number beginning with 214 (e.g., 2145551234), the call
is routed to a IAD(8)-U() ETU with IP Address 10.1.0.100.
7.
When all parameters have been configured, select Submit.
8.
Select the System tab, then select the Reset the Card option. The ETU goes
through a reboot cycle and may take a few minutes.
9.
Disconnect the crossover cable and connect the IAD (8)-U( ) ETU to the LAN
port.
The ETU is now ready for operation.
S
ECTION
4
S
HUTDOWN
P
ROCEDURE
The IAD(8)-U( ) ETU is a hot swappable ETU and can be removed from the KSU
without powering down the IAD(8)-U( ) ETU or the KSU system.
If the KSU requires a system reset, the IAD(8)-U( ) ETU will come back online.