IPK II IAD(8)-U( ) Configuration
S
ECTION
1
C
ONFIGURING
IAD(8)-U( ) ETU
When installed for the first time, the IAD(8)-U( ) ETU, comes up with factory set
default parameters as shown in
Table 4-1 Factory Network Settings
.
In this configuration, the ETU cannot run in any randomly given environment, and its
parameters must be redefined before the IAD(8)-U( ) ETU can work in your
environment.
The required parameters can be set by using your web browser and connecting to the
default IP Address (192.168.1.100) in the browser navigation address bar. Refer to
Appendix A Web-Based Setup and Configuration
for a detailed description of this
configuration utility.
S
ECTION
2
PC P
ARAMETERS
The initial configuration is performed using a PC (or laptop computer) connected to
the IAD(8)-U( ) ETU using a crossover Ethernet cable (one-to-one connection) or
connecting with a hub. Make sure that the PC has the networking parameters set as
shown in
Table 4-2 Network Settings for the PC
.
Table 4-1 Factory Network Settings
Computer Name
neciad
IP Address
192.168.1.100
Subnet Mask
255.255.255.0
Default Gateway
192.168.1.1
Table 4-2 Network Settings for the PC
IP Address
192.168.1.XXX
Subnet Mask
255.255.255.0