DS2000 03.20.07 Release Notes
Software Corrections in 03.20.07
DS2000 Release Notes
29
◆
03.20.07
software versions 03.10.08 and above, these soft keys would appear but were not functional unless
these Class of Service options were enabled (Y).
Name Programming
Entering Long Name Aborts Name Programming
Software version corrects a problem in version 03.10.08 and above where the system could exit pro-
gramming while the installer was entering a long name. In version 03.20.07, the system will wait
approximately 30 seconds after the last character is entered before aborting the programming mode.
Flash Key Operation
When programming names, press
FLASH
to delete the character to the right of the cursor. In prior soft-
ware versions 03.10.08 and above,
FLASH
key operation when editing a name was not consistent.
Programming
Program 0301 Data Entry Errors
Software version 03.20.07 corrects the following program entry problem that occurred when pro-
gramming
0301-Modem Installed
in prior 03.**.** versions:
1.
Enter programming mode and select program 0301.
2.
Press
HOLD
or
Vol Up
repeatedly until you see
MODEM INSTALLED
.
3.
You cannot change the setting for
0301-Modem Installed
until you press
Vol Up
to bypass
the option, then
Vol Down
to return to it.
Program 0501 Data Entry Errors
Software version 03.20.07 corrects the following program entry problem that occurred when pro-
gramming
0501-Single Digit Access
in prior 03.**.** versions:
1.
Enter programming mode and select program 0501.
2.
For digit 2, set
FUNCTION
Type to
3
(Line Group) + Vol Up.
3.
Change the setting of
SINGL DGT ACCESS
for the digit 2 (9=Yes, 6=No) +
HOLD
.
4.
Press
CONF
to exit.
5.
Repeat steps 1-3 to check your entry. The programmed value has not changed.
To save your entry in prior software versions, press
Vol Up
in step 3 instead of
HOLD
.
Program 1704 Data Entry Errors
Software version 03.20.07 corrects a data entry problem in prior 03.**.** versions in which using
Vol Up
and
Vol Down
to quickly scroll through
1704-DSS Console Key Assignments
will cause
programming to freeze. Pressing
CONF
will release the freeze.
Program 1802 Data Entry Errors
Software version 03.20.07 corrects a data entry problem in
1802-Outgoing ANI ID
for E1 trunks
that occurred in prior 03.**.** versions. After editing the entry, the blinking cursor would remain
after exiting the edit mode. This is an option for E1 MFC dialing that is not used in North America.
Program 8003 Data Entry Errors
Software version 03.20.07 corrects an out-of-range data entry error in prior 03.**.** versions when
programming
8003-Trunk Number
. For example, in DS2000 the
fi
rst trunk number could display
as 240 instead of 1. This is now corrected.