DS2000 03.20.07 Release Notes
Software Corrections in 03.20.07
30
◆
03.20.07
DS2000 Release Notes
Program 9903 Allows ATRU PCB In Slot 1
In prior versions of 03.**.** software, the system would auto-ID an ATRU PCB plugged into slot
1, even though slot 1 is reserved for a 16DSTU PCB. In addition, program
9903-Set Up Trunks
would recognize the installed PCB. In software version 03.20.07, an ATRU PCB plugged into slot 1
is ignored by the system, will not auto-ID, and will not be recognized by program 9903.
Speed Dial
4-Digit System Speed Dial Bin Displays Wrong Name
Software version 03.20.07 corrects a problem with 4-digit System Speed Dial numbers in prior
03.**.** versions in which names would be assigned to the wrong bins in
1101-System Speed Dial
Numbers
.
Pressing Super Display Soft Key When No Block Assigned Resets System
In prior software versions, if a Super Display Telephone user pressed
SP DIAL 1
or
SP DIAL 2
and
their extension had no Speed Dial block assigned in
1802-Speed Dial Block
, the system would
reset. This is corrected in software version 03.20.07.
Station Message Detail Recording
Abbreviated Caller ID Status Messages
Software version 03.20.07 corrects the following Caller ID Status Messages on the SMDR report:
T1 Trunking
Out Of Frame Sync Recovery Improved
Software version 03.20.07 incorporates enhancements that improves the ability of the T1 PCB to
recover from an Out of Frame Sync condition.
Prior 03.**.** Versions
03.20.07
Priv
Private Number
Out
Out of Area Number