Cooling
2-13
The main logic module contains the single master power controller for the cell. The
master power controller
y
Controls and monitors the power supplies, and monitors the voltages on all cell
components
y
Responds when someone presses the power button (to turn the power on or off)
y
Monitors and controls the fans
y
Monitors thermal sensors
y
Communicates with the management system
200-Volt Redundancy and AC Source Options
A second AC/DC 12-volt power supply provides n+1 DC redundancy. If one power
supply fails, the cell can continue operating at normal levels with the other power supply.
A second AC source can be configured to provide AC redundancy. The two power
supplies can also be configured for a non-redundant 100-volt operation.
In addition, with a second power supply, you can increase system availability by
attaching each power supply to a different power source, for example, to a different
uninterruptible power supply (UPS). If one power source fails or is interrupted, the cell
continues processing using the other power source.
In a redundant 200V configuration, you can replace individual power supplies while a
partition is running within that cell.
Partitions and Power
Partitions are made up of one or more cells. If a system contains multiple partitions, one
partition can be powered off while the other partitions continue their processing.
Clustering software also helps ensure continuous processing.
Uninterruptible Power Supply (UPS)
UPSs help sites minimize system downtime caused by AC disturbances. A UPS uses
batteries to provide AC to the system if the AC input is lost or disturbed. The length of
time a system runs on a UPS depends on the capacity of the UPS and the amount of
power the system needs.
The decision to provide alternate power sources, standby power generation, UPS, or a
combination of these should be based on the economic consequences of a system
interruption caused by a power outage or brownout (low voltage). A service
representative can assist with this analysis.