background image

Note: 

This step requires a good amount of 

force and the 

key

 may bend slightly - keep 

tightening.

07 
Wrap the adapter

 

(4–5 wraps)

IMPORTANT:

 Prior to wrapping the 

adapter, visually inspect the threads 
on the narrow end (un-notched end) of 
the adapter for damage. Contact Nebia 
Support if you suspect the threads are 
damaged.

Wrap the narrow threads of the 

adapter 

4 to 5 times

 in a 

clockwise direction

 with 

plumber’s tape

, leaving the first thread 

exposed.

08 
Screw in the adapter

Safety recommendation:

 

Wear gloves 

during step 8.

Screw the end of the 

adapter

 wrapped  

in 

plumber’s tape

 into the water outlet.  

Lock the 

key

 inside the 

adapter's

 notch 

to tighten the 

adapter

 as shown below. 

Turn the 

key

 clockwise until the 

adapter

 

is very tight. To ensure that the 

adapter

 

is secure, continue turning the 

key

 

with both hands until you can’t turn it 
anymore.

Caution:

 This step is very important. A 

poorly wrapped adapter can lead to leaks.  
To watch a close up video of this step, 
please visi

nebia.com/install

09a 
Fasten the collar

Peel the protective layer off of the  

gasket

 and slide it over the 

adapter

adhering it to the wall. 

Screw the 

collar

 onto the 

adapter

 by 

hand until it just touches the 

gasket

 

(do not over-tighten).

09b 
If you have a ledge

Peel the protective layer off the 

gasket

 

and slide it over the 

adapter

, adhering  

it to the wall. 

Slide the 

spacer(s)

 you selected over  

the 

adapter

 on top of the 

gasket

Then, screw the 

collar

 onto the 

adapter

 

by hand until it just touches the 

gasket

 

(do not over-tighten).

8

Summary of Contents for Spa Shower 2.0

Page 1: ...Setup Guide How to install your Nebia Spa Shower 2 0...

Page 2: ...rface area of water all while saving up to 65 of water compared to a standard shower Head swivel Sliding arm Bracket Wand Flow rate gallons per minute Nebia Spa Shower 2 0 0 9gpm Overhead 65 Savings 1...

Page 3: ...P pipe connection in your wall this is standard in most bathrooms Wall surface cannot be slate Before you get started We know that installing a shower may seem intimidating Don t worry The Nebia Spa S...

Page 4: ...ours preferably Uninstall your old showerhead Shower ring Shower arm Grasp the shower arm firmly with both hands Turn counterclockwise until the shower arm comes out of the wall Then remove the shower...

Page 5: ...o recommend that you keep all of the parts in order to install Nebia 2 0 in a different location in the future HEAD DOCK WAND COLLARS SPACERS ADAPTERS SCREWS GASKET L KEY KEY ALCOHOL WIPE FILTER ARM C...

Page 6: ...kes contact with a flat surface If this is difficult rest the bracket arm on its side on a flat surface To prevent scratches a towel can be placed underneath the unit 03 Position shower head Position...

Page 7: ...from this connection when the shower is turned ON if the tube is not fully seated 06 Attach arm cover Snap arm cover in place Ensure the hose exits the rear of the arm cover through the notch Insert...

Page 8: ...s to the correct adapter and collar combination If you fall on the line between two letters choose the longer combination In some cases the water outlet may be in a part of the wall that is recessed f...

Page 9: ...e adapter as shown below Turn the key clockwise until the adapter is very tight To ensure that the adapter is secure continue turning the key with both hands until you can t turn it anymore Caution Th...

Page 10: ...ould keep pushing the bracket into the collar until the indicator turns gray To verify this wall connection give the top of the bracket a strong tug The unit should stay firmly attached to the wall If...

Page 11: ...k 15 Connect the wand Insert the hose into the bottom of the bracket You will hear a click Remember to give the dock adhesive 24 hours to set Then place the wand on the dock with the on off button fac...

Page 12: ...water cleaning If you live in an area with hard water you may find that minerals deposits build up from time to time We have designed two custom cleaning caps that will make it easier to remove these...

Page 13: ...at the connection point to the Wand Hose The other check valve Neoperl 31 4285 00000 is located in the handle of the Wand between the Wand Hose and the Wand Switch If the check valve in the Wand hand...

Page 14: ......

Reviews: