Document Number
DCV-00202
Date Released
Oct. 2016
Revision Number/Security level
R01 S2
Retrofit G6+InvencoLink GVR Advantage (US) Installation Guide
4 Installation Guide
1. Please ensure all safety procedures are followed per requirement by the customer before
installing the retrofit kit.
2. Remove power to Pump and follow the OSHA Lock-out/Tag-out procedures.
3. This installation will require a panel replacement. The panel will be removed from the door and
replaced with a pre-built panel with the OPT pre-fitted.
4.1
Disassembly Procedure
Before installation of the equipment can take place, the existing electronic payment assembly
must be removed from the dispenser. This section covers the removal of the Gilbarco CRIND
components including:
The CRIND Panel Door with components (card reader, display, etc.)
The printer
The T19501-Gx Monochrome display CPU board or other installed screens.
The CRIND Rack Assembly with wire assemblies
1.
At the main disconnect panel, disconnect all power to the dispenser and the pump servicing the
dispenser. Tag all disconnected breakers to prevent others from reconnecting power.
2.
Identify the A Side of the dispenser.
Note
:
For the purposes of this manual, Side One of the dispenser refers to the side with the
manufacturer’s label.
3.
Identify whether the pump is a “Wide Frame” or “Narrow Frame” version from the pictures below –
some steps below vary depending which version you have:
Failure to turn off the unit during installation of the kit may cause injury or bodily harm from electrical shock.
Ensure that all power to the unit is switched off before opening the door of the unit and during kit installation.
WARNING