EB1 Circuit Breaker

$29.95

Electronic circuit breaker for use on DCC layouts only.

Features of the EB1:

Provides short circuit protection for one power district 

Trip current adjustable for 2.5 to 8 Amps

Easy hookup using screw terminals, no soldering

Status indication LED

Additional output for remote LED

Optional manual reset

Adjustable short circuit response time  

Adjustable power-up response time to accommodate startup of sound
decoder equipped locomotives

This book, schematics and artwork copyright 2009 NCE Corp., Webster, NY 14580

Age

14+

05240225

05240225

Warning: This product contains chemicals known to the state of California to cause

cancer, birth defects or other reproductive harm.

Summary of Contents for EB1v1

Page 1: ...ring Status indication LED Additional output for remote LED Optional manual reset Adjustable short circuit response time Adjustable power up response time to accommodate startup of sound decoder equipped locomotives This book schematics and artwork copyright 2009 NCE Corp Webster NY 14580 Age 14 05240225 05240225 Warning This product contains chemicals known to the state of California to cause can...

Page 2: ...ack feeder wires every 8 10 feet when using code 83 or larger rail size If you re using code 70 or smaller rail we suggest feeders every 6 feet Insufficient feeders can cause enough voltage drop to prevent the circuit breaker from working The drawing below shows booster DCC power and track connections as well as hookups for optional manual reset and a remote status LED Note The screw terminals mar...

Page 3: ...s indicator LED near the SETUP connector The LED will light steadily if everything is OK A flashing LED indicates the circuit breaker for the power district has tripped LED off usually indicates the DCC power booster is turned off Optional External Status Indicator You may connect an LED for use as a remote status indicator to terminals 3 and 4 of the the EB1 This LED will duplicate the actions of...

Page 4: ...me delay between the occurrence of a short circuit and the time the track actually gets shut down The EB1 comes factory set to 16mS 16 milliseconds 16 thousandths of a second This setting has been chosen because it can be used without problem on most layouts You can lengthen this delay from 16ms 1 60th second out to 512mS 1 2 second Program CV129 to the number of milliseconds divided by 16 you des...

Page 5: ...f CV135 0 the table is disabled CV135 default 0 Custom startup table initial on time CV136 default 4 Custom startup table initial off time CV137 default 8 Custom startup table 2nd on time CV138 default 4 Custom startup table 2nd off time CV139 default 16 Custom startup table 3rd on time CV140 default 4 Custom startup table 3rd off time CV141 default 32 Custom startup table 4th on time CV142 defaul...

Page 6: ...for a period of 1 year As the circumstances under which it is installed can not be controlled failure of the device due to installation problems can not be warranted This includes misuse miswiring or operation under loads beyond the design range of the device For warranty or non warranty replacement send the device and any payment if required to NCE Warranty Center 82 Main Street Webster New York ...