background image

Two ways to setup the EB1:

Method 1:
Any DCC system that has OPs mode programming (Program On the Main) for locomotives
can program CVs.  Whenever the “SETUP” shunt is installed the EB1 will respond to loco
OPS mode programming no matter what locomotive address is used.  We recommend
choosing an address that is not in use on your layout (we use 9999).    Remember that the
shunt must be installed to use this method of setting CVs.  Do not forget to remove the
shunt when done programming
.

Method 2:
If you have an NCE (or other system) that supports OPs mode programming of accessories
you can program CVs without having to install the “SETUP” shunt.  

The EB1 comes from the factory preprogrammed to the accessory address of 2044 (the
accessory broadcast address).  
To change the address:

Install the “SETUP” shunt

Press SELECT ACCY on your controller

Type in the new address you want to EB1 to use followed by ENTER

Press 1 (for NORMAL) when prompted on your controller

Remove the shunt 

The EB1 will now respond to Accessory Programming at the address you just programmed.

You will not need to install the shunt again to program CVs when using PROGRAM
ACCESSORIES mode on an NCE system.

Fine Tuning the EB1

CV129 - Adjustment of short circuit response time (if necessary):
You can adjust the time delay between the occurrence of a short circuit and the time the track
actually gets shut down.  The EB1 comes factory set to 16mS (16 milliseconds = 16
thousandths of a second).  This setting has been chosen because it can be used without
problem on most layouts.   You can lengthen this delay from 16ms (1/60th second) out to
512mS (1/2 second).    Program CV129 to the number of milliseconds (divided by 16) you
desire between 16mS and 500mS. A value of 1 = 16mS, a value of 32 = 512mS, etc.

CV130 - Adjustment of short circuit shutdown time (if necessary):
You can adjust the time the track power stays off after a short circuit is detected.  The EB1
comes factory set to 2 seconds.  This setting has been chosen because it can be used
without problem on most layouts.   You can change this delay from 16mS to 4 seconds.    
Program CV130 to the number of milliseconds (divided by 16) you desire. A value of 1 =
16mS, a value of 128= 2 seconds, 256 = 4 seconds, etc.

CV131 - Manual reset enable.
If CV131 is set to 0 the manual reset is disabled and the EB1 will automatically try to turn on
track power after a short circuit.  If CV131 is set to 1 the EB1 will not automatically restore
track power after a short circuit until a connection (usually with a pushbutton) is made
between terminals 1 and 2 of the four position terminal strip.  You can also turn the track
power back on by selecting the accessory address and setting the accessory to ON (also
known as Normal, Thrown or +) . 

**Last revised:  23 April 2012

Page 4

EB1

Summary of Contents for EB1v1

Page 1: ...ring Status indication LED Additional output for remote LED Optional manual reset Adjustable short circuit response time Adjustable power up response time to accommodate startup of sound decoder equipped locomotives This book schematics and artwork copyright 2009 NCE Corp Webster NY 14580 Age 14 05240225 05240225 Warning This product contains chemicals known to the state of California to cause can...

Page 2: ...ack feeder wires every 8 10 feet when using code 83 or larger rail size If you re using code 70 or smaller rail we suggest feeders every 6 feet Insufficient feeders can cause enough voltage drop to prevent the circuit breaker from working The drawing below shows booster DCC power and track connections as well as hookups for optional manual reset and a remote status LED Note The screw terminals mar...

Page 3: ...s indicator LED near the SETUP connector The LED will light steadily if everything is OK A flashing LED indicates the circuit breaker for the power district has tripped LED off usually indicates the DCC power booster is turned off Optional External Status Indicator You may connect an LED for use as a remote status indicator to terminals 3 and 4 of the the EB1 This LED will duplicate the actions of...

Page 4: ...me delay between the occurrence of a short circuit and the time the track actually gets shut down The EB1 comes factory set to 16mS 16 milliseconds 16 thousandths of a second This setting has been chosen because it can be used without problem on most layouts You can lengthen this delay from 16ms 1 60th second out to 512mS 1 2 second Program CV129 to the number of milliseconds divided by 16 you des...

Page 5: ...f CV135 0 the table is disabled CV135 default 0 Custom startup table initial on time CV136 default 4 Custom startup table initial off time CV137 default 8 Custom startup table 2nd on time CV138 default 4 Custom startup table 2nd off time CV139 default 16 Custom startup table 3rd on time CV140 default 4 Custom startup table 3rd off time CV141 default 32 Custom startup table 4th on time CV142 defaul...

Page 6: ...for a period of 1 year As the circumstances under which it is installed can not be controlled failure of the device due to installation problems can not be warranted This includes misuse miswiring or operation under loads beyond the design range of the device For warranty or non warranty replacement send the device and any payment if required to NCE Warranty Center 82 Main Street Webster New York ...

Reviews: