17
Set Control of Relays
When you change the state of a relay manually from this screen, you have taken
control of the particular relay and the Taralist controller will not be able to control
it. Using the ‘Set Control of Relays’ in the center section above, set the relay to be
controlled by the Computer or the Taralist Device. It is important to always
return control of the relay back to the Taralist device after you are done manually
controlling it.
Who Has Control of the Relays?
It is important to know if the Taralist device or your computer has control of the
relays. Use the ‘Who Has Control of Relays?’ section on the right to read who has
control of each individual relay. Simply click the ‘Who Controls Relay 1’ button
and the information will be updated to the right of the button telling you who has
control of Relay 1. You may also read who has control of all 8 relays in a bank by
clicking the ‘Who Controls All Relays’ button.
Custom Software Control
Custom software may be written to take computer control of the relays by using
the ProXR Lite Command Set. Custom Software may be written on any software
platform capable of sending RS 232 bytes of data through a Com Port or through
direct TCP/IP communications for Ethernet Devices.