Working range with frequency fuel level sensors, Hz 

1 - 3000 

USB interface for settings, control, data transfer and diagnostics 

yes 

RS-485 digital interface 

yes 

RS-232 digital interface 

yes 

CAN digital interface 

no 

1-Wire interface 

yes 

Number  of  outputs  of  the  “open  collector”  type  for  the  external  devices 

control 

Maximum switching current by the control outputs, mA 
 

500 

Maximum switching voltage by the control outputs, V 

48 

Built-in 3-axis accelerometer 

yes 

Maximum impact loading measured by the device, g 

Performance specifications 

Enclosure protection level 

IP54 

Maximum allowable overload during impacts, g 

24 

Storage temperature with the battery

6

 ,

o

0 … +40 

Storage temperature without the battery, 

o

-40 … +85 

Operating temperature with the battery, 

o

-20 … +60 

Operating temperature without the battery, 

o

-40 … +85 

Temperature at which the battery is possible to charge, 

o

0 … +50 

Maximum allowable humidity level at 35 

o

C, % 

95 

Device dimensions with connectors, mm 

102х57х22 

Device weight, kg 

0,090 

 

1.

 

Optional 

2.

 

If maximum operating voltage is exceeded the power protection is activated. The device continues to work, but is 

powered by the battery.  

3.

 

If GPRS operates in poor communications, peak consumption (10 ms), consumption of the device can accede 500 mA. 

4.

 

Attention!

 

Lithium  polymer  battery  (Li-Po)  is  used  in  the  device.  The  following  rules  must  be  observed  during  its 

operation: not to heat, keep away from sources of heat, not to throw the battery into the fire, not to expose to direct 

sunlight. The device, for power of which Li-Po battery is used, cannot be used in high humidity, high and low ambient 

temperatures. Operation is permitted under the conditions specified by the manufacturer. Not to hit, not to deform, 

not to disassemble, not to close contacts.  

5.

 

Protection against battery charge while it is overcooled or overheated.  

6.

 

The mode in which information received through RS-232 and RS-485 interfaces is not processed by the device, and is 

buffered and transmitted to the server as it is.  

7.

 

When the device is stored and used outside the specified temperatures, it is recommended to turn it off and remove 

the battery from the device to avoid damage to the battery and to the device. 

 

 

 

 

Summary of Contents for SMART S-2433

Page 1: ...GPS GLONASS TRACKING EQUIPMENT SMART S 2433 Operations manual Installation and connection of the device v1 0 MOSCOW 2020...

Page 2: ...terested in constantly improvement of the manufactured products quality Please contact our technical support by email address support navtelecom ru should you have any questions or problems with the d...

Page 3: ...11 2 DEVICE CONNECTON 12 2 1 Installation 12 2 2 SIM card installation and operation 13 2 3 Power connection 13 2 4 Universal inputs connection 14 2 4 1 Analog sensors connection 14 2 4 2 Discrete se...

Page 4: ...de control of cargo safety by comprehensive measures improving driver and passenger s safety 1 3 Operational principles The device during its operation continuously monitors the status of the connecte...

Page 5: ...t consumption at 12 V voltage in operation mode on average3 mA 80 Current consumption at 12 V voltage with turned off GLONASS and GSM modules is no more than mA 25 Maximum current consumption at 12 V...

Page 6: ...090 1 Optional 2 If maximum operating voltage is exceeded the power protection is activated The device continues to work but is powered by the battery 3 If GPRS operates in poor communications peak co...

Page 7: ...iniUSB connector for connection with a computer SIM card holder slot with ejector yellow button In the upper part of the device unit Figure 3 there are three indicators system indicator SYS modem oper...

Page 8: ...ce cable with MiniUSB connector 1 5 Passport 1 6 Package 1 Figure 4 14 pin connector of Microfit 14 Figure 5 Interface cable with MiniUSB connector Some cases may require connection of additional equi...

Page 9: ...Figure 9 External LED Figure 10 Temperature sensor Figure 11 TouchMemory contact key reader The manufacturer reserves the right to complete the devices with equipment whose set appearance and characte...

Page 10: ...e 12 15 1 front cover 2 fixing hole 3 system LED indicator 4 GSM LED indicator 5 GLONASS GPS LED indicator 6 14 pin connector 7 MiniUSB connector 8 SIM card 1 ejector holder 9 SIM card holder 1 extern...

Page 11: ...Figure 14 Figure 15...

Page 12: ...is prohibited to apply a voltage more than 50 V to the device universal inputs because it may lead to the failure of the device Outputs OUT1 and OUT2 open collector type are designed to control low cu...

Page 13: ...erature more than 60 C for example near heating systems etc It is also prohibited to place the device in a sealed container without heat dissipation It is prohibited to install tracker in places with...

Page 14: ...o the power supply through a 1 A fuse not included in standard equipment set During installation the power supply should be connected the last turn when all the other equipment is already connected Co...

Page 15: ...Analog sensor s connection 2 4 2 Discrete sensors connection The device allows to connect any type of sensors that have two steady states on activated and off normal The voltage thresholds at which t...

Page 16: ...c R1 R2 UIN C1 CPU_pull up VDD Figure 22 Connection of normally closed NC sensors Profiles Discrete NC and Discrete NO allow to work with sensors which when turned on or off close the input to supply...

Page 17: ...be used as an ignition 14 7 13 6 12 5 11 4 10 3 9 8 2 1 Fuse 1 U Ignition switch UIN1 Alarm button GND GND Car battery Figure 25 Connection of the ignition lock and alarm button Digital inputs are co...

Page 18: ...2 5 Built in accelerometer There are virtual sensors based on the built in accelerometer three axis acceleration sensor soft and strong impact sensors displacement sensor and tilt sensor in the devic...

Page 19: ...d Buzzer without built in generator can be connected only to OUT1 because only this line has opportunity to modulate the control signal for the buzzer Buzzer with built in generator can be connected t...

Page 20: ...Designation of the external relay contacts When voltage is applied to control contacts relay is activated and closes or opens the electrical circuit with power contacts Power contacts are always marke...

Page 21: ...90 keys via interface 1 Wire Each DS1990 key is a chip with a unique identification number stitched into it at the manufacturing plant by which the device identifies this sensor Saving the key codes i...

Page 22: ...d of the bus that is opposite to the connected device it should be closed by the last plug in sensor 14 7 13 6 12 5 11 4 10 3 9 8 2 1 Fuse 1A GND Car battery Temperature sensors DS1820 Data Data Data...

Page 23: ...ed to reconnect them by swapping the RX and TX contacts If there is any doubt which sensor line is Tx and which Rx it is possible check this with a multimeter in the voltage measurement mode The measu...

Page 24: ...A RS485 Line B FLS Line A RS485 Line B Figure 40 Connection diagram of fuel level sensors by RS 485 interface In the fuel sensor the periodic data output mode must be turned off and the network addre...

Page 25: ...cond off There is a registration in the cellular network of the operator Weak signal 2 short flashes 1 second off There is a registration in the cellular network of the operator Medium quality signal...

Reviews: