background image

8

ENG

manager

After this time, the pairing is disabled again.

Copying a fingerprint database:

The  ARX-manager  allows  you  to  copy  fingerprint 

databases for two reasons. The first one is to make 

a  backup  copy  of  the  fingerprints  which  can  be 

used  in  case  of  device  malfunction  or  accidental 

resetting of the device. If you use more fingerprint 

readers,  the  database  can  be  simply  copied  into 

other  readers  without  adding  the  fingerprints  to 

each reader separately. The fingerprint database is 

encrypted and therefore protected against misuse. 

If someone steals your database, they cannot use it 

because it can be unlocked only by the administrator 

in the base. Fingerprints or templates are encrypted 

in such a way that it is impossible to reconstruct a 

fingerprint image out of them.

In  the  menu,  select  “options”,  then  choose 

 

»

“database” and then “export”. A page will open 

allowing  you  to  enter  the  location  where  you 

want  to  save  your  fingerprint  database  to. 

Confirm the location by pressing “open” and the 

fingerprint database will be saved to the desired 

location.

If  you  want  to  save  the  fingerprint  database  in 

 

»

another  reader,  connect  to  it  and  in  the  menu 

select  “options”,  then  “database”  and  then 

“import”.  A  page  will  open  for  you  to  find  the 

saved  fingerprint  database.  When  you  find  it 

press  “open”  and  the  fingerprint  database  will 

be copied to the reader but it will remain locked. 

A message will be displayed saying “swipe your 

finger”.  Then,  one  of  the  administrators  has  to 

swipe their finger over the reader. Once they have 

been  identified,  the  database  will  unlock  and  a 

message saying “successful” will be displayed. A 

list of all users will show. All other settings have to 

be configured separately. 

Update:

If  updates  for  your  device  are  available  and  you 

want  to  update  it,  choose  “update”  in  the  menu 

and the device will alert you that the history of the 

events will be deleted. If you want to continue, press 

“forward” and the device will automatically connect 

to the Internet and download and install the latest 

version of the software.

Important:

If  the  performance  of  this  function  is  interrupted 

by an unsuccessful identification or a time out, the 

whole procedure has to be repeated. 

When a user is enrolling their fingerprints, the pause 

between  each  swipe  of  the  finger  over  the  sensor 

should be at least two seconds.

3.6. MAINTENANCE

The  device  does  not  require  any  special 

maintenance. The sensor is cleaned by every swipe 

of the finger but in extreme cases (when the ARX-

manager is used with greasy hands) it can be cleaned 

with a moist or dry soft cloth. Even mild cleansers 

can be used.

Aggressive  cleansers,  solvents  or  acids  must  not 

be used for cleaning purposes. Rubbing the sensor 

with  hard  or  sharp  objects  can  result  in  device 

malfunction and loss of warranty entitlement.

Summary of Contents for ARX-manager

Page 1: ...MANUAL DE USUARIO...

Page 2: ...nical data capacity 1000 fingerprints 256 bit encryption high speed identification operating temperature range 30 C to 60 C 22 F to 140 F operating humidity range to 90 prints remain in the database e...

Page 3: ...eir finger over the sensor at this height The exterior unit should be protected from rain and should not be exposed to direct sunlight 1 2 INTERIOR UNIT MOUNTING The interior unit fits on the DIN rail...

Page 4: ...enrolled 3 DEVICE MANAGEMENT 3 1 PROPER USE ThethermalsensorusedintheARX managerenables excellent fingerprint scanning in any conditions and simultaneously minimizes the chances of misuse Nevertheless...

Page 5: ...device is secured and for any subsequent connections one of the administrator fingerprints will have to be used You can add new fingerprints to the existing administrator or enrol a new administrator...

Page 6: ...oose a date after which the user will be automatically deleted from the device or you can also leave this option blank By pressing add the enrolment process is started and the user swipes their finger...

Page 7: ...rent purposes Connect your mobile device to the ARX manager In the menu select options and then choose history A page with a list of the last 100 events will open with the most recent events on the to...

Page 8: ...n and the fingerprint database will be copied to the reader but it will remain locked A message will be displayed saying swipe your finger Then one of the administrators has to swipe their finger over...

Page 9: ...flashes continuous ARX manager is connected to the mobile device and ready to be managed Green Yes flashes 1 x 1 x 1 s Administrator or user has been successfully identified The fingerprint template...

Page 10: ...f the finger has not been swiped the ARX manager will return to the previous function after fifteen seconds If the enrolment procedure has not been carried out in less than one minute the device will...

Page 11: ...in freescan mode The database is full A new fingerprint can be enrolled when some of the existing fingerprints in the database are deleted A fingerprint stored in the database is not identified The f...

Page 12: ...nded for the time the product was at service If the respective product has undergone a major service intervention or if the product was replaced a new warranty is issued to the customer for a 24 month...

Page 13: ...of the customer Adress of the customer Stamp and signature of the seller ARX manager was manufactured by NAVKOM d o o Prijateljeva 24 1000 Ljubljana Slovenia EU info navkom si www navkom si Product ty...

Page 14: ...is cable is close to other high power cables Maximum length of cable between exterior and interior unit is 150 m Three connection wires between exterior and interior unit are marked 1 12 positive pole...

Page 15: ...onnection with exterior unit 3 12 V Connection with exterior unit 4 12 V Can be used for el Lock or pushbutton 5 Connection for pushbutton With this pushbutton we trigger relay number 1 6 Contact of r...

Page 16: ...supplied with power from interior unit We can supply power to the electric lock from interior unit only if it s consumption is less than 500 mA If electric lock has higher consumption than 500 mA we n...

Page 17: ...lock from interior unit only if it s consumption is less than 500 mA If electric lock has higher consumption than 500 mA we need to connect additional power supply look diagram 4 As option we can conn...

Page 18: ...ock In this case we need to connect push button for exit Only relay 1 is triggered with this button Because magnet has higher consumption than 500 mA additional power supply is required Diagram 3 ADDI...

Page 19: ...higher consumption than 500 mA additional power supply is required If we connect 2 readers and 2 electric locks we can use the same way of connection We use this diagram also if we use 1 reader and 1...

Page 20: ...Cesta v Log 19 1351 Brezovica Slovenija DISTRIBUIDOR AUTORIZADO AFB DOMOTICS S L C Garcilaso 213 2 1 08027 Barcelona Spain 34 934 081 741 www afbdomotics com...

Reviews: