High-Voltage Cables
Figure 12.
High-Voltage Cables (Viewed from Under Vehicle)
WARNING: To prevent personal injury and / or death, NEVER cut or attempt to breach high-voltage
batteries, high-voltage components, or high-voltage cables when high voltage is present.
High-voltage cables are colored in ORANGE and / or ORANGE with stripes. DO NOT cut, breach, or stress
ORANGE high-voltage components unless high-voltage in the corresponding zone has been isolated:
•
High voltage in Zone 1 is isolated when Level 1 Manual Service Disconnects (MSDs) are disconnected.
•
High voltage in Zone 2 is isolated when Level 2 MSDs are disconnected.
•
NEVER cut or attempt to breach high-voltage batteries, high-voltage components, or high-voltage cables in
Zone 3.
Refer to
Disable Direct Hazards
on the following pages for detailed instructions.
4328810R1
12
© 2021 Navistar, Inc. All rights reserved. All marks are trademarks of their respective owners.