Figure 13: Depiction of GPS Distribution Amplifier
Install Connectors on Cables
Install connectors on both ends of each cable. For LMR 600 cables, install EZ-600 N-type male
connectors. For LMR 400 cables, install EZ-400 N-type male connectors. Steps for installing
both types of connectors can be found in
Appendix K
. For reference, Appendix L also provides a
list of vendors who can make cables.
Sweep Individual Cables
Sweep each individual cable, the RFS (8) and CAL main feeder and jumper cables, to check for
line loss. Follow the instructions for sweeping the cables provided in
Appendix C
, entering the
results in the RFS System Test Form. Check continuity of the data/power cable. When finished,
cover the cable connectors for protection until they are connected to the RFS or GPS.
GPS 1
Polyphaser
Distribution Amp
GPS 2
Polyphaser
Distribution Amp
BTS 1
BTS 2
BTS 3
SHELTER