rev. 05 of 15-01-20 / pag. 1 

 

 

EW076.305 

 

 

 

Wall-mounted  
Carbon Monoxide 

 

detectors 

for homes, recreational vehicles 

 

and similar sites 

 

ESN.F.O..

 

 

Conformity standard EN50291 

___________________________________________________________________________________________ 

Electronic carbon monoxide detectors with time-varying alarm threshold and three calibration points for 
homes, recreational vehicles and similar sites. 
230Vac, 12Vac/dc or 12…24Vac/dc power supply, depending on the model. 
Relay command output with voltage free contact, so suitable for any kind of solenoid valve or other 
command and alarm device. 
Possibility of parallel connection of more than one detector, also for monitoring different gases. 

___________________________________________________________________________________________ 

Use

 

The  ESN.F.O..  detectors  can  be  used  to  provide  a  visual/audible  alarm  and  to  control 
other  alarm  transmitters  or  actuating  devices,  in  the  presence  of  carbon  monoxide 
concentrations that pose a hazard to humans from gas poisoning. 

_____________________________________________________________________________________________ 

Operation

  

The  detector  will  enter  a  warm-up  phase  after  power-up;  this  will  take  about  5  seconds 
and during this time the detector activates all  its visual and audible alarms in sequence. 
At the end of the initial test and warm-up phase (about one  minute), the detector enters 
normal  operation  mode,  and  will  continue  in  this  state  until  it  detects  gas  or  until  the 
detector fails. 

Gas detection 

In  conformity  with  the  requirements  of  European  standard  EN50291,  the  monitoring 
algorithm used for gas detection is 

“time-varying alarm threshold”

 that considers both 

the concentration of the gas and the time it is detected. 
A threshold level one, set at about 50ppm

(1)

, sets off the time meter; if the concentration 

remains  at  this  value  the  alarm  will  activate  after  a  time  limit  of  60  to  90  minutes;  at  a 
concentration level of 100ppm the detector will enter alarm condition after a time limit of 
10  to  40  minutes;  if  the  concentration  level  is  300ppm  (or  higher)  the  alarm  will  go  off 
immediately (within 3 minutes). 
Intermediate concentration values require proportionately intermediate alarm times. 
Once  the  alarm  condition  ceases  to  exist,  the  detector  will  be  restored  to  normal 
operation. 

(1) 

ppm =

 

parts per million of concentration of gas in the air.

 

___________________________________________________________________________________________ 

Power supply

 

Detector 

230Vac

 

12Vac/dc

 

12…24Vac/dc

 

Type A 

ESN.F.O.A 

ESN.F.O.A.D 

ESN.F.O.A.E 

Type B 

ESN.F.O.B 

ESN.F.O.B.D 

ESN.F.O.B.E 

Type A

 = with command output to SPDT relay 8A / 250Vac 

Type

 

B

 = only visual/audible alarm (no command output) 