SERVICE AND STORAGE

Infrequent Service

If the unit is used infrequently, difficult starting 
may result. To eliminate hard starting, follow 
these instructions:
1. Run the generator at least 30 minutes every 
    month.
2. Run the generator, then close the fuel shut-off 
    valve and allow the unit to run until the engine 
    stops.
3. Move the fuel selector to the "OFF" position.

Long Term Storage

It is important to prevent gum deposits from forming 
in essential fuel system parts such as the carburetor, 
fuel  hoses  or  tank  during  storage.  Also,  experience 
indicates that alcohol-blended fuels (called gasohol, 
ethanol  or  methanol)  can  attract  moisture,  which 
leads  to  separation  and  formation  of  acids  during 
storage.  Acidic  gas  can  damage  the  fuel  system  of 

an engine while in storage.

When  the  generator  set  is  not  being  operated, 
or is being stored for more than one month, follow 
these instructions to avoid engine problems:

1-

ADD

 a properly formulated commercially 

FUEL 

STABILIZER

 to the tank if it is not already added.

2-Operate the engine for 5-10 minutes to circulate 
treated fuel into fuel lines and carburetor before 
shutdown.
3- After engine cools down, remove all gasoline 
from the fuel tank. Use a commercially available, 
non-conductive vacuum siphon.

DANGER

Drain fuel into approved container outdoors, 
away from open flame. Be sure engine is cool. 
Do not smoke.

4-

FUEL  STARVATION:

    Turn  fuel  selector  switch 

to “

GAS

” position. Start and run the generator until it 

stops  from  lack  of  gasoline.  This  will  dry  out  all 
remaining gasoline in tank, fuel lines and carburetor. 

5-Turn  fuel  selector  switch  to  “

OFF

”  position. 

Fully close the LPG cylinder knob if it is open and 
disconnect  LPG  cylinder  from  the  generator.

6-Allow the unit to cool entirely before cleaning 
and storage.  
7-Change oil with recommended grade oil.
8-Remove spark plug and pour about one teaspoon 
of engine oil through the spark plug hole, then pull 
the recoil starter several times to distribute the oil for 
lubricating  the  cylinder.  Reattach  the  spark  plug. 
Pull  recoil  slowly  until  resistance  is  felt.  This  will 
close  the  valves  so  moisture  cannot  enter  engine 

9-Cover the unit and store in a clean, dry place 
out of direct sunlight. 

NEVER USE WATER TO 

CLEAN GENERATOR.

cylinder. Gently release recoil starter.

We  recommend  always  using  a  fuel  stabilizer. 

FUEL STABLIZER

 will minimize the formulation 

of  fuel  gum  deposits  during  storage,  the  fuel 
stabilizer  can  be  added  to  the  gasoline  in  the 
fuel  tank,  or  into  the  gasoline  in  a  storage 
container.

NOTE:

If  it  is  not  practical  to  empty  the  fuel  tank  and 
the  unit  is  to  be  stored  for  some  time,  use  a 
commercially  available  FUEL  STABILIZER  added 
to  the  gasoline  to  increase  the  life  of  the  gasoline. 
Run  the  unit  for  5-10  minutes  to  circulate  treated 
gasoline  into  the  fuel  lines  abs  carburetor  before 
shutdown. 

DO NOT STORE GENERATOR WITHOUT 

FUEL  STABILIZER  IN  FUEL  SYSTEM  INCLUDING 
TANK, FUEL LINES AND CARBURETOR.

Any  damages  or  hazards  caused  by  using 
improper  fuel,  improperly  stored  fuel,  and/ 
or improperly formulated stabilizers, are not 

Do not store gasoline from one season to 
another season.

covered by manufacturer's warranty. 

Summary of Contents for NG2500

Page 1: ...rating equipment Ensure engine is stopped and level before performing any maintenance or service IMPORTANT Record product information to reference when ordering parts or obtaining warranty coverage Se...

Page 2: ......

Page 3: ...rting the Generator Recoil Start 17 Starting the Generator Electric Start 18 Connecting Electrical Loads 19 Stopping the Engine 20 Low Oil Shutdown 20 Do Not Overload Generator 20 Introduction Removal...

Page 4: ...rtant Safety Information The manufacturer cannot possibly anticipate every possible circumstance that might involve a hazard The warnings in this manual and the tags and decals affixed to the unit are...

Page 5: ...SAFETY PRECAUTIONS Page 02 WARNING POISONOUS GAS HAZARD WARNING WARNING English The engine exhaust from this product contains chemicals to cause cancer birth defects or other reproductive harm...

Page 6: ...ONLY use outside and downwind far away from windows doors and vents Direct exhaust away from occupied spaces INCORRECT USAGE Do not operate in any of the following locations Near any door window or v...

Page 7: ...ressure in tank Fill or drain fuel tank outdoors DO NOT overfill tank Allow space for fuel expansion If fuel spills wait until it evaporates before starting engine Keep fuel away from sparks open flam...

Page 8: ...ath or serious injury and or property damage Contact with muffler area could cause burns resulting in serious injury DO NOT touch hot parts and AVOID hot exhaust gases Allow equipment to cool before t...

Page 9: ...luded Your gasoline powered generator ships with the following parts 1 Axle pin 2 2 Wheel 2 3 Flat Washer 2 4 Cotter pin 2 5 Wrench for Spark plug 1 6 Double Open wrench 10mm 12mm 1 7 Handle Pin 8 Cot...

Page 10: ...Refer to the following instructions and pictures to remove the attached engine support brackets red under the engine 3 You may discard these brackets as it is no longer required for normal operation o...

Page 11: ...es some assembly prior to usage If problems arise when assembling the generator call F E G H K 1 Before adding wheels tip the generator on its side 2 Slide the axle pin A through the wheel B 3 Slide t...

Page 12: ...positive battery cable red boot is securely tightened to the positive battery post Make sure boot is over battery post 2 Remove bolt M5X10 and M5 nut from black cable ring 3 Remove vinyl cap from the...

Page 13: ...nd air filter box 5 Fuel Valve 6 Air Filter 7 NAVIGATOR OHV Engine 8 Recoil Starter 9 Flat Free Wheel 10 Oil Filler Cap 11 Control Panel 12 13 Battery Handle English We are always working to improve o...

Page 14: ...ctric start model only To start engine press and hold the switch in the START ll position the engine will crank and attempt to start When the engine starts release the switch to the RUN l position Con...

Page 15: ...Factor Voltage Regulator Alternator Type Running Watts Starting Watts Engine Engine Type Displacement Low Oil Shutdown Ignition System Starting System Fuel Capacity Fuel Tank Lubricating Oil Capacity...

Page 16: ...arning device or stop the engine If generator shuts off and the oil level is within specifications check to see if generator is sitting at an angle that forces oil to shift Place on an even surface to...

Page 17: ...e or explosion Wipe up any spilled fuel immediately If fuel spills wait until it evaporates before starting engine Keep fuel away from sparks open flames pilot lights heat and other ignition sources C...

Page 18: ...etal decking or steel work DO NOT touch bare wires or receptacles DO NOT use generator with electrical cords which are worn frayed bare or otherwise damaged DO NOT operate generator in the rain or wet...

Page 19: ...protected from the weather Keep exhaust pipe clear of foreign objects Keep generator away from open flame Keep generator on a stable and level surface WARNING Surge Protection Voltage fluctuation may...

Page 20: ...When starting engine pull cord slowly until resistance is felt and then pull rapidly to avoid kickback 4 Turn the fuel valve to the ON l position 7 Pull the starter cord slowly until resistance is fe...

Page 21: ...evices plugged in or turned on 4 Turn the fuel valve to the ON l position 5 Flip the engine switch to the RUN l position 7 Move the choke lever to the START position 8 Press and hold the engine switch...

Page 22: ...lug in and turn on the desired 230 Volt AC single phase 50Hz electrical loads It is better to attach the item with largest load first This unit has been pretested and adjusted to handle its full capac...

Page 23: ...2 Contact an Authorized Service Dealer 3 DO NOT operate engine until oil level is corrected If oil level is below LOW mark on dipstick 1 Add oil to bring level to HIGH mark 2 Restart engine and if th...

Page 24: ...endations Regular maintenance will improve the performance and extend the life of the generator See any authorized dealer for service The generator s warranty does not cover items that have been subje...

Page 25: ...certain laboratory animals Thoroughly wash exposed areas with soap and water a Drain oil by removing the drain plug and the oil filler cap while the engine is warm Change engine oil every 100 hours fo...

Page 26: ...n and strainer cup with gasoline c Tightly fasten the cup to main body making sure to avoid fuel leak SCREEN O ring CUP BODY b Remove spark plug using provided wrench Inspect spark plug for damage and...

Page 27: ...Battery Replacement English 1 Remove the spark plug wire from spark plug 2 Remove the nut and bolt from the negative and positive posts 3 Loosen and remove the screw A and nut B on the battery holding...

Page 28: ...m lack of gasoline This will dry out all remaining gasoline in tank fuel lines and carburetor 5 Turn fuel selector switch to OFF position Fully close the LPG cylinder knob if it is open and disconnect...

Page 29: ...ion 2 Move fuel shutoff lever to ON l position 3 Fill crankcase to proper level or place generator on level surface 4 Clean or replace air cleaner 5 Fill fuel tank 6 Drain fuel tank and carburetor fil...

Page 30: ...P N 323745451 Rev 01...

Reviews: