64 NFC Service Manual
Version 1.0
4.12.13 DHW Heat Exchanger
Part
Check Point
Function
Water heated in the primary/secondary heat exchanger is circulated to the plate heat exchanger,
where the heat of hot water and tap water are exchanged so that hot water is available.
Failure Event
1. Water leakage through a crack.
2. Improper heat transfer can cause the heat exchanger to produce cold water.
Effects
Temperature fluctuations in the hot water outlet and/or leakage.
Error Code
E016, E030, E353
Diagnostic
The plate heat exchanger filters out impurities within the space heating pipes to prevent heating
problems caused by impurities. The leak in plate heat exchanger will cause pressure in the space
heating side to increase to tap water pressure level.