background image

Page 9

MAINTAIN ALL EQUIPMENT: Preventative maintenance is the key to smooth operating equipment 

as well as keeping the product in safe operating condition.  Failure to conduct preventative mainte-

nance by the owner may cause the product to operate in an unsafe manner.  Equipment needs to be 

inspected and maintained at regular intervals per the preventative maintenance schedule provided 

in this manual.

Cleaning

Keeping your Nautilus® Inspiration Strength® units clean is an important component of preventa-

tive maintenance and the overall aesthetics of your product. While your clients will appreciate clean 

equipment free of sweat, dirt and other contaminants proper care and cleaning will extend the life 

of your product and reduce premature aging and wear.

•  Upholstery should be cleaned daily with a mild soap and water mix or an approved antibacterial cleaner. 

•  Hand grips should be cleaned daily with a mild soap and water mix or an approved antibacterial cleaner.

•  Main frame should be cleaned weekly with mild soap and water mix dampened cloth or an approved antibacte-

rial cleaner to remove all dust and accumulated contaminants.

•  Guide rods should be cleaned monthly with a cotton cloth prior to lubrication. It is critical to remove all old 

lubricants and accumulated contaminants prior to applying lubrication.

•  Internal tower and weight stack should be cleaned once every six months with a mild soap and water damp-

ened cloth to remove all dust and accumulated contaminants. Caution should be taken to not leave excess 

moisture after cleaning.

•  Note – do not use cleaners that contain solvents, alcohol or abrasives. 

Inspection

Visual inspection of your Inspiration Strength units will insure a safe environment for your clients 

and alert you to any issues that may require maintenance prior to equipment failure. Proper, timely 

visual inspection is a critical component to the long term care of your product.

•  Cables should be inspected weekly for damage including cracked vinyl housing, fraying metal strands, twisting 

or excessive rubbing on pulleys. Any incident of wear should elicit immediate replacement of damaged cable.

•  Cables may become loose over time and require adjustment to maintain proper function – refer to you specific 

installation manual for cable tension instructions.

•  Fasteners, hardware and attachments should be checked monthly for looseness. Tighten as required using 

appropriate tools. 

•  Handgrips should be checked for wear or damage monthly and replaced as needed.

•  Upholstery should be inspected for wear or damage monthly and replaced as needed. 

•  Pulleys should be inspected every six months for integrity, cracking or rubbing leading to excessive wear. Any 

incident of wear should elicit immediate replacement of damaged pulley.

•  Main frame and tower should be inspected every six months for signs of unusual wear, corrosion or structural 

integrity issues. 

• 

Summary of Contents for IPTE3

Page 1: ...OWNER S MANUAL Inspiration Triceps Extension Core Health Fitness...

Page 2: ...Page 1 PRODUCT SPOTLIGHT 2 IMPORTANT SAFETY INSTRUCTIONS 3 IMPORTANT LABEL LOCATIONS 5 STRENGTH PRODUCT USE 6 OPERATIONS 7 MAINTENANCE 8 SUPPORT AND SERVICE 11 WARRANTY 12 TABLE OF CONTENTS...

Page 3: ...ension Overall Weight Stack Weight Width Length Height User Weight 690 lb 314 kg 200 lb 91 kg 56 142 cm 43 109 cm 64 163 cm 0 400 lbs 0 181 kgs All products may be covered by US and Foreign Patents an...

Page 4: ...mounting surface that does not rest thoroughly on the floor using flat washers DO NOT force the foot to contact the ground with anchors Fasteners must have a minimum of 500 lbs tensile capac ity be a...

Page 5: ...rn or damaged parts must be replaced immediately or the equipment removed from service until the repair is made 5 Ensure all adjustment and locking features are properly secured before using the equip...

Page 6: ...EL LOCATIONS 731 0512 TRICEPS EXTENSION TRICEPS EXTENSION PRIMARY CAUTION PRUDENCE VORSICHT THIS MACHINE IS EQUIPPED WITH LOCK N LOAD TECHNOLOGY FOR WEIGHT SELECTION SWITCH DESIRED PLATE TO THE ON POS...

Page 7: ...e sole responsibility of the purchaser of Nautilus Inspiration Strength products to read the owner s manual review the following pages and instruct all individuals whether they are the end user or sup...

Page 8: ...PLACED FLAT AND EVENLY ACROSS THE ARM PAD ALIGN ELBOWS WITH THE AXIS OF ROTATION POINTS AND INSURE THAT THE DESIRED PRE STRETCH IS ACHIEVED SELECT A COMFORTABLE HAND POSITION WITH THE WRISTS STRAIGHT...

Page 9: ...examined for damage and wear and repaired It is the sole responsibility of the owner of this equipment to ensure that regular maintenance is performed Worn or damaged parts must be replaced immediate...

Page 10: ...weight stack should be cleaned once every six months with a mild soap and water damp ened cloth to remove all dust and accumulated contaminants Caution should be taken to not leave excess moisture aft...

Page 11: ...her neglected or in many cases facilities over lubricate without cleaning the old dirty lubricant off prior to applying the new This results in a build up of dirty contaminants that will cause prematu...

Page 12: ...structional Videos and other information https support corehandf com INSPIRATION Contact Information CORE HEALTH FITNESS 4400 NE 77th Avenue Suite 300 Vancouver WA 98662 Telephone 888 678 2476 http ww...

Page 13: ...shall be borne solely by the original consumer purchaser Defective part s must remain available for inspection until the claim is finalized Whenever claims are settled CORE HEALTH FITNESS LLC reserve...

Page 14: ...2018 CORE HEALTH FITNESS LLC PART NUMBER 19 7965 REV B...

Reviews: