Remove jam from B2 Reject Transport Section
▶
Zone
⑦
, B2 Bottom Transport Section of BM2.
▶
Location LED E or F Blinks
1. If there is a jam on Zone
⑦
-1,
⑦
-2, push the lever L7 in the arrow direction as
shown in the picture and open the BM2 Transport Section.
2. Remove a jammed Note or foreign substances.
3. After checking if the jammed Note is removed, completely close BM2 Transport
Section as shown in the picture.
4. If it is necessary to remove the inside jam of REJECT
Once you open BM2 using L7,
Check bills and remained substance
Remove bills and remained substance.
Close BM2
(Caution; Risk of pinching hand)